A study case: Seismic evaluation of existing six-story office building with flat plate structural system

Abstract. Indonesia is one of the countries with a relatively high frequency of earthquakes, which can impact buildings and infrastructure. With the ongoing updates to regulatory codes, there will be an elevation in the level of safety factors in building design. Concurrently, there will be an increased prevalence of incorporating seismic hazards into the design of new buildings. Apart from that, earthquake loads can cause the performance of flat-plate structures to decrease until they collapse. Therefore, in this research, a case study of the existing office building with a flat plate structural system built in 1998 will undergo a seismic evaluation based on ASCE 41-17 to determine whether the building's performance is still safe. The office building was evaluated at the Collapse Prevention performance level for the BSE-2E seismic hazard (975-year period) according to ASCE 41-17. The evaluation occurred in three stages: tier 1, tier 2, and tier 3. The pushover analysis demonstrates the use of linear and nonlinear static procedures in structural analysis. The evaluation indicated that the current office building could meet the specified performance level; however, several beam and column structural components still required fixing.

Authors

Institutions

Publication Details

Journal
Materials research proceedings
Published
2025-02-12
DOI
https://doi.org/10.21741/9781644903414-16
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A study case: Seismic evaluation of existing six-story office building with flat plate structural system

Jim Andrew
Materials research proceedings
Seismic Performance and Analysis
article

A study case: Seismic evaluation of existing six-story office building with flat plate structural system

Jim Andrew
article en

Abstract

Abstract. Indonesia is one of the countries with a relatively high frequency of earthquakes, which can impact buildings and infrastructure. With the ongoing updates to regulatory codes, there will be an elevation in the level of safety factors in building design. Concurrently, there will be an increased prevalence of incorporating seismic hazards into the design of new buildings. Apart from that, earthquake loads can cause the performance of flat-plate structures to decrease until they collapse. Therefore, in this research, a case study of the existing office building with a flat plate structural system built in 1998 will undergo a seismic evaluation based on ASCE 41-17 to determine whether the building's performance is still safe. The office building was evaluated at the Collapse Prevention performance level for the BSE-2E seismic hazard (975-year period) according to ASCE 41-17. The evaluation occurred in three stages: tier 1, tier 2, and tier 3. The pushover analysis demonstrates the use of linear and nonlinear static procedures in structural analysis. The evaluation indicated that the current office building could meet the specified performance level; however, several beam and column structural components still required fixing.

Materials research proceedingsVol. 48
Universitas Trisakti (ID)
Openalex Percentile: Top 97%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.