This paper proposes a system architecture for a portable microwave stroke detector operating within the 0.5-2 GHz frequency band. The system is divided into two components: the front-end detection equipment and the back-end control equipment. The detector utilizes a frequency domain confocal imaging algorithm to define the imaging area and accurately estimate brain signals by compensating for signal loss at the point of incidence. Experimental validation was performed on healthy volunteers, solution-filled models, and human specimens. The results demonstrate that the system can accurately locate hemorrhages and achieve rapid stroke detection without false positives.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/icsidp62679.2024.10868778
Citations
1
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Portable Microwave Imaging System for Stroke Detection

Rui Zong, Xiang Gao, Fan Li, Heng Liu et al.
1 citations
Microwave Imaging and Scattering Analysis
0.18
article

Development and Validation of a Portable Microwave Imaging System for Stroke Detection

Rui Zong, Xiang Gao, Fan Li, Heng Liu, Zhizhen Qin, Zekun Zhang
article en
1 citations

Abstract

This paper proposes a system architecture for a portable microwave stroke detector operating within the 0.5-2 GHz frequency band. The system is divided into two components: the front-end detection equipment and the back-end control equipment. The detector utilizes a frequency domain confocal imaging algorithm to define the imaging area and accurately estimate brain signals by compensating for signal loss at the point of incidence. Experimental validation was performed on healthy volunteers, solution-filled models, and human specimens. The results demonstrate that the system can accurately locate hemorrhages and achieve rapid stroke detection without false positives.

Beijing Institute of Technology (CN), Chinese PLA General Hospital (CN)
Research and Development
Openalex Percentile: Top 49%
Microwave Imaging and Scattering Analysis
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Validation of a Portable Microwave Imaging System for Stroke Detection — Rui Zong, Xiang Gao, et al. · (2024) | TGRS Research Map | TGRS