Teaching learning optimization technique FOPID controlled Cuk and SEPIC converter-based PF rectification

The foremost cause of harmonic contamination is the ample utilization of loads of non-linear type such as static power converters. Because of this load, the input power factor (PF) decreases heavily as they draw a current of non-sinusoidal in nature. This article gives a general presentation investigation of two PF rectification (PFR) converter (PFRC) geographies: Cuk type and single-ended primary-inductance converter or SEPIC type converter. The average current control (ACC) technique is utilized here. Notwithstanding, for control of output voltage, techniques like conventional proportional integral derivative controller (PIDC) or fractional order proportional integral derivative controller (FOPIDC) are used, and the gains of the controller are calculated using a novel teaching learning optimization technique (TLOT), considering integral time absolute error (ITAE). The analysis of both PFRC acted in Simulink/MATLAB and the estimated converters are studied under consistent and dynamic state conditions. The FOPIDC Cuk PFRC is providing 2.97% of THD compared to other converters.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Published
2025-02-12
DOI
https://doi.org/10.11591/ijpeds.v16.i1.pp311-320
Primary Topic
Advanced Control Systems Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Teaching learning optimization technique FOPID controlled Cuk and SEPIC converter-based PF rectification

Fathy A. Syam, Nimay Chandra Giri, Sangram Kishore Routray, E. S. Elwakil et al.
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Advanced Control Systems Design
article

Teaching learning optimization technique FOPID controlled Cuk and SEPIC converter-based PF rectification

Fathy A. Syam, Nimay Chandra Giri, Sangram Kishore Routray, E. S. Elwakil, Soumya Ranjan Das, Alok Kumar Mishra
article en

Abstract

The foremost cause of harmonic contamination is the ample utilization of loads of non-linear type such as static power converters. Because of this load, the input power factor (PF) decreases heavily as they draw a current of non-sinusoidal in nature. This article gives a general presentation investigation of two PF rectification (PFR) converter (PFRC) geographies: Cuk type and single-ended primary-inductance converter or SEPIC type converter. The average current control (ACC) technique is utilized here. Notwithstanding, for control of output voltage, techniques like conventional proportional integral derivative controller (PIDC) or fractional order proportional integral derivative controller (FOPIDC) are used, and the gains of the controller are calculated using a novel teaching learning optimization technique (TLOT), considering integral time absolute error (ITAE). The analysis of both PFRC acted in Simulink/MATLAB and the estimated converters are studied under consistent and dynamic state conditions. The FOPIDC Cuk PFRC is providing 2.97% of THD compared to other converters.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer EngineeringVol. 16(1)
Siksha O Anusandhan University (IN), Maharaja Engineering College (IN), Sri Sri University (IN), Electronics Research Institute (EG), Centurion University of Technology and Management (IN)
Affordable and clean energy
Openalex Percentile: Top 97%
Advanced Control Systems Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Teaching learning optimization technique FOPID controlled Cuk and SEPIC converter-based PF rectification — Fathy A. Syam, Nimay Chandra Giri, et al. · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering (2025) | TGRS Research Map | TGRS