Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum

A microfluidic system for detecting sodium ions (Na<sup>+</sup>) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na<sup>+</sup> concentration in human serum. A small volume (10 μL) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na<sup>+</sup> concentration is then inversely derived from the measured A<sub>555</sub>/A<sub>666</sub> absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na<sup>+</sup> concentration within the range of 1-200 mM, with a correlation coefficient of R<sup>2</sup> = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R<sup>2</sup> = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na<sup>+</sup> detection methods, making it highly promising for point-of-care (POC) testing applications.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-02-12
DOI
https://doi.org/10.3390/bios15020104
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum

Chin‐Chung Tseng, Chia-Chun Lee, Lung‐Ming Fu, Kuan-Hsun Huang et al.
2 citations
Biosensors
Analytical Chemistry and Sensors
1.47
article

Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum

Chin‐Chung Tseng, Chia-Chun Lee, Lung‐Ming Fu, Kuan-Hsun Huang, Cheng-Xue Yu
article en
2 citations

Abstract

A microfluidic system for detecting sodium ions (Na<sup>+</sup>) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na<sup>+</sup> concentration in human serum. A small volume (10 μL) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na<sup>+</sup> concentration is then inversely derived from the measured A<sub>555</sub>/A<sub>666</sub> absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na<sup>+</sup> concentration within the range of 1-200 mM, with a correlation coefficient of R<sup>2</sup> = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R<sup>2</sup> = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na<sup>+</sup> detection methods, making it highly promising for point-of-care (POC) testing applications.

BiosensorsVol. 15(2)
National Cheng Kung University Hospital (TW), National Cheng Kung University (TW)
Openalex Percentile: Top 22%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines