Frameless Stereotaxy in Stereoelectroencephalography Using Intraoperative Computed Tomography

<b>Background:</b> Pharmacoresistant epilepsy affects approximately one-third of all epilepsy patients, and resective surgery may offer favorable outcomes for carefully selected patients with focal epilepsy. The accurate identification of the epileptogenic zone (EZ) is essential for successful surgery, particularly in cases where non-invasive diagnostics are inconclusive. Invasive diagnostics with stereoelectroencephalography (SEEG) offer a reliable approach to localizing the EZ, especially in MRI-negative cases. <b>Methods</b>: This retrospective study analyzed the data of 22 patients with pharmacoresistant epilepsy who underwent frameless stereotactic SEEG electrode implantation with automated CT-based registration between September 2016 and November 2024. For measuring accuracy, Euclidean distance, radial deviation, angular deviation, and depth deviation were calculated for each electrode. <b>Results:</b> A total of 153 depth electrodes were implanted, targeting various cortical regions. The median Euclidean distance at the entry point was 1.54 mm (IQR 1.31), with a radial deviation of 1.33 mm (IQR 1.32). At the target level, the median Euclidean distance was 2.61 mm (IQR 1.53), with a radial deviation of 1.67 mm (IQR 1.54) and depth deviation of 0.95 mm (IQR 2.43). Accuracy was not significantly affected by electrode order, anatomical location, skull thickness, or intracranial length. <b>Conclusions</b>: These findings demonstrate that frameless stereotactic SEEG electrode implantation is safe and feasible for identifying the EZ. The integration of automatic intraoperative CT-based registration ensures precision. While maintaining workflow efficiency, it achieves accuracy comparable to frame-based methods. Further studies with larger cohorts are warranted to validate these results and assess their impact on surgical outcomes.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2025-02-12
DOI
https://doi.org/10.3390/brainsci15020184
Citations
6
Primary Topic
Epilepsy research and treatment
Type
article
Field-Weighted Citation Impact
8.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frameless Stereotaxy in Stereoelectroencephalography Using Intraoperative Computed Tomography

Susanne Knake, Alexander Grote, Katja Menzler, Daniel Delev et al.
6 citations
Brain Sciences
Epilepsy research and treatment
8.83
article

Frameless Stereotaxy in Stereoelectroencephalography Using Intraoperative Computed Tomography

Susanne Knake, Alexander Grote, Katja Menzler, Daniel Delev, Barbara Carl, Miriam H. A. Bopp, Marko Gjorgjevski, Christopher Nimsky
article en
6 citations

Abstract

<b>Background:</b> Pharmacoresistant epilepsy affects approximately one-third of all epilepsy patients, and resective surgery may offer favorable outcomes for carefully selected patients with focal epilepsy. The accurate identification of the epileptogenic zone (EZ) is essential for successful surgery, particularly in cases where non-invasive diagnostics are inconclusive. Invasive diagnostics with stereoelectroencephalography (SEEG) offer a reliable approach to localizing the EZ, especially in MRI-negative cases. <b>Methods</b>: This retrospective study analyzed the data of 22 patients with pharmacoresistant epilepsy who underwent frameless stereotactic SEEG electrode implantation with automated CT-based registration between September 2016 and November 2024. For measuring accuracy, Euclidean distance, radial deviation, angular deviation, and depth deviation were calculated for each electrode. <b>Results:</b> A total of 153 depth electrodes were implanted, targeting various cortical regions. The median Euclidean distance at the entry point was 1.54 mm (IQR 1.31), with a radial deviation of 1.33 mm (IQR 1.32). At the target level, the median Euclidean distance was 2.61 mm (IQR 1.53), with a radial deviation of 1.67 mm (IQR 1.54) and depth deviation of 0.95 mm (IQR 2.43). Accuracy was not significantly affected by electrode order, anatomical location, skull thickness, or intracranial length. <b>Conclusions</b>: These findings demonstrate that frameless stereotactic SEEG electrode implantation is safe and feasible for identifying the EZ. The integration of automatic intraoperative CT-based registration ensures precision. While maintaining workflow efficiency, it achieves accuracy comparable to frame-based methods. Further studies with larger cohorts are warranted to validate these results and assess their impact on surgical outcomes.

Brain SciencesVol. 15(2)
Philipps University of Marburg (DE), Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Helios Dr. Horst Schmidt Kliniken Wiesbaden (DE), Center for Behavioral Brain Sciences (DE), Technische Hochschule Mittelhessen (DE)
Openalex Percentile: Top 2%
Epilepsy research and treatment
8.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.