Validation of Cable-Driven Experimental Setup to Assess Movements Made with Elbow Joint Assistance

This article investigates a cable-driven experimental setup to simulate elbow joint assistance in the sagittal plane provided by an exosuit. Cable-driven exosuits, particularly fabric-based designs, significantly enhance rehabilitation by enabling targeted joint exercises and promoting functional recovery. To achieve an optimal design, these devices require an analysis of the cable tension, reaction forces, and moments and their dependency on the anchor position. This study presents a cable-driven experimental setup with two rigid bars and variable anchor positions, designed to mimic the human forearm, upper arm, and elbow joint, to evaluate the performance of a potential cable-driven exosuit. Based on the experimental setup, a static model was developed to validate the measured cable tension and estimate the reaction force at the joint and the moments at the anchor positions. Furthermore, based on the observations, an optimization problem was defined to identify optimal anchor positions to improve the exosuit’s design. The optimal position on the forearm and upper arm is studied between 15% and 50% distance from the elbow joint. Our findings suggest that prioritizing user comfort requires both anchor points to be as far away from the elbow joint as possible, i.e., 50% distance, whereas, for optimal exosuit performance, the forearm anchor position can be adjusted based on the joint angle while keeping the upper arm anchor position at the farthest point. The findings in the current work can be used to decide the anchor point position for designing an elbow exosuit.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-02-12
DOI
https://doi.org/10.3390/app15041892
Citations
4
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Cable-Driven Experimental Setup to Assess Movements Made with Elbow Joint Assistance

Yannick Aoustin, Deep Seth, Sreejan Alapati, Sanjeevi Nakka
4 citations
Applied Sciences
Muscle activation and electromyography studies
2.70
article

Validation of Cable-Driven Experimental Setup to Assess Movements Made with Elbow Joint Assistance

Yannick Aoustin, Deep Seth, Sreejan Alapati, Sanjeevi Nakka
article en
4 citations

Abstract

This article investigates a cable-driven experimental setup to simulate elbow joint assistance in the sagittal plane provided by an exosuit. Cable-driven exosuits, particularly fabric-based designs, significantly enhance rehabilitation by enabling targeted joint exercises and promoting functional recovery. To achieve an optimal design, these devices require an analysis of the cable tension, reaction forces, and moments and their dependency on the anchor position. This study presents a cable-driven experimental setup with two rigid bars and variable anchor positions, designed to mimic the human forearm, upper arm, and elbow joint, to evaluate the performance of a potential cable-driven exosuit. Based on the experimental setup, a static model was developed to validate the measured cable tension and estimate the reaction force at the joint and the moments at the anchor positions. Furthermore, based on the observations, an optimization problem was defined to identify optimal anchor positions to improve the exosuit’s design. The optimal position on the forearm and upper arm is studied between 15% and 50% distance from the elbow joint. Our findings suggest that prioritizing user comfort requires both anchor points to be as far away from the elbow joint as possible, i.e., 50% distance, whereas, for optimal exosuit performance, the forearm anchor position can be adjusted based on the joint angle while keeping the upper arm anchor position at the farthest point. The findings in the current work can be used to decide the anchor point position for designing an elbow exosuit.

Applied SciencesVol. 15(4)
École Centrale de Nantes (FR), Mahindra Group (India) (IN), Nantes Université (FR)
I-Hub Foundation for Cobotics
Openalex Percentile: Top 11%
Muscle activation and electromyography studies
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.