From technical challenges pursued in development of performance evaluation of optical 3d CMS

ISO 10360-13, dedicated for acceptance and reverification test of optical three dimensional coordinate measuring system (Optical 3D CMS), has been published since 2021. The development needs to take into account outcomes from a couple of technical challenges, with intention to realize test protocols for effectively verifying performance of Optical 3D CMS. Those particularly include i) experimental re-validation of length measuring performance test sparsely performed according to previously published standards, ii) dependency in measuring performance on different concatenation pathways for connecting multiple of single view length measurements indispensable for realizing a longer measurement range. An experimental study is carried out by adopting a prototype material standard having intentionally dense observation points in two-dimensional planar manner. The results show notable difference in the capture efficiency in length measurement error, depending on residual of the system qualification applied to CMSs. Another experimental study is conducted for comparing concatenated length measurement results between two different concatenation scenarios, one conservatively optimized, and the other purposely detoured. The experimental result supports informative effectiveness of the combination of two different concatenation pathways.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2025-02-12
DOI
https://doi.org/10.1016/j.measen.2024.101660
Primary Topic
Semiconductor Lasers and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From technical challenges pursued in development of performance evaluation of optical 3d CMS

Masahiko Abe
Measurement Sensors
Semiconductor Lasers and Optical Devices
article

From technical challenges pursued in development of performance evaluation of optical 3d CMS

Masahiko Abe
article en

Abstract

ISO 10360-13, dedicated for acceptance and reverification test of optical three dimensional coordinate measuring system (Optical 3D CMS), has been published since 2021. The development needs to take into account outcomes from a couple of technical challenges, with intention to realize test protocols for effectively verifying performance of Optical 3D CMS. Those particularly include i) experimental re-validation of length measuring performance test sparsely performed according to previously published standards, ii) dependency in measuring performance on different concatenation pathways for connecting multiple of single view length measurements indispensable for realizing a longer measurement range. An experimental study is carried out by adopting a prototype material standard having intentionally dense observation points in two-dimensional planar manner. The results show notable difference in the capture efficiency in length measurement error, depending on residual of the system qualification applied to CMSs. Another experimental study is conducted for comparing concatenated length measurement results between two different concatenation scenarios, one conservatively optimized, and the other purposely detoured. The experimental result supports informative effectiveness of the combination of two different concatenation pathways.

Measurement SensorsVol. 38
Mitutoyo Corporation (Japan) (JP)
Openalex Percentile: Top 98%
Semiconductor Lasers and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.