High-energy-density acoustofluidic device using a double-parabolic ultrasonic transducer

High-acoustic-energy-density acoustofluidic devices are necessary to make this technology a viable option for clinical applications in the biomedical field. We present a mechanical interface that enables delivery of a high-amplitude acoustic field inside a fluid cavity by translating the vibrations from two large piezoelectric elements into a microfluidic chip. The study comprises both experimental characterization of a double-parabolic metallic acoustic waveguide and simulations of its working mechanism in two dimensions. We could focus 4.9-μm polystyrene particles at a flowrate of 5 ml/min, corresponding to an average retention time of 13.5 ms for particles in the actuated area. Moreover, we measured the acoustic energy density in the channel at stopped-flow condition, obtaining an average value of 1207 J<i>/</i>m<sup>3</sup> and a maximum value of 2977 J<i>/</i>m<sup>3</sup> with an input electrical power of 1.5 W. By comparing the simulation results with laser-Doppler vibrometer measurements, we confirmed that transverse sound waves play a significant role in the working mechanism of the double-parabolic structure, thus paving the way for further future optimization of the waveguide design.

Authors

Institutions

Publication Details

Journal
Physical Review Applied
Published
2025-02-12
DOI
https://doi.org/10.1103/physrevapplied.23.024031
Citations
8
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
5.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-energy-density acoustofluidic device using a double-parabolic ultrasonic transducer

Per Augustsson, Ola Jakobsson, Takeshi Morita, Wei Qiu et al.
8 citations
Physical Review Applied
Microfluidic and Bio-sensing Technologies
5.39
article

High-energy-density acoustofluidic device using a double-parabolic ultrasonic transducer

Per Augustsson, Ola Jakobsson, Takeshi Morita, Wei Qiu, Enrico Corato
article en
8 citations

Abstract

High-acoustic-energy-density acoustofluidic devices are necessary to make this technology a viable option for clinical applications in the biomedical field. We present a mechanical interface that enables delivery of a high-amplitude acoustic field inside a fluid cavity by translating the vibrations from two large piezoelectric elements into a microfluidic chip. The study comprises both experimental characterization of a double-parabolic metallic acoustic waveguide and simulations of its working mechanism in two dimensions. We could focus 4.9-μm polystyrene particles at a flowrate of 5 ml/min, corresponding to an average retention time of 13.5 ms for particles in the actuated area. Moreover, we measured the acoustic energy density in the channel at stopped-flow condition, obtaining an average value of 1207 J<i>/</i>m<sup>3</sup> and a maximum value of 2977 J<i>/</i>m<sup>3</sup> with an input electrical power of 1.5 W. By comparing the simulation results with laser-Doppler vibrometer measurements, we confirmed that transverse sound waves play a significant role in the working mechanism of the double-parabolic structure, thus paving the way for further future optimization of the waveguide design.

Physical Review AppliedVol. 23(2)
Lund University (SE), The University of Tokyo (JP)
European Commission, Stiftelsen för Strategisk Forskning, Vetenskapsrådet, Tokyo Institute of Technology, European Research Council, Japan Society for the Promotion of Science
Openalex Percentile: Top 5%
Microfluidic and Bio-sensing Technologies
5.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.