Fabrication, Characterization, and Clinical Assessment of Ultrathin Skin-Conformable Tattoo Electrodes for ECG Monitoring

In recent years, there has been a surge in interest surrounding the advancement of gel-free, ultrathin, skin-conformable tattoo electrodes for continuous and extended monitoring of ECG signals. This development aims to mitigate the limitations associated with traditional electrodes. However, all of these results are limited to data from individual subjects. Hence, replicability is reduced by individual variability due to a small sample size, which may lead to inconclusive results. Consequently, the suitability of these outcomes for clinical validation has been inadequately investigated. In this study, an ultrathin, gel-free, skin-conformable PEDOT:PSS-based tattoo electrode was fabricated and characterized. A preclinical skin irritation test of the PEDOT:PSS-based tattoo electrode was performed before clinical assessment. Next, we accessed the performance of these tattoo electrodes involving 34 healthy volunteers and compared the ECG signals acquired from these ultrathin electrodes with those recorded by traditional Ag/AgCl electrodes. The fabricated tattoo electrode is approximately 10 μm thick and has a skin–electrode impedance of 72 KΩ at 50 Hz. The preclinical skin irritation study confirmed that the film of PEDOT:PSS is nontoxic, noncorrosive, and biocompatible with rabbit skin. In healthy volunteers, the data points from the sample population all cluster closely around the bias line, and we observed no significant systematic error associated with the ECG measurement. This PEDOT:PSS-based skin-conformal tattoo electrode retained its characteristics even after continuous wear for up to 24 h during routine activities, and the electrodes remained stable even after 60 days of storage. Altogether, our findings confirmed the suitability of these skin-conformal PEDOT:PSS-based tattoo electrodes for ECG monitoring.

Authors

Institutions

Publication Details

Journal
ACS Applied Electronic Materials
Published
2025-02-12
DOI
https://doi.org/10.1021/acsaelm.4c02263
Citations
5
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
3.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication, Characterization, and Clinical Assessment of Ultrathin Skin-Conformable Tattoo Electrodes for ECG Monitoring

Uttam Kulhari, Sundareswaran Loganathan, Bidya Dhar Sahu, L. N. Sharma et al.
5 citations
ACS Applied Electronic Materials
Advanced Sensor and Energy Harvesting Materials
3.37
article

Fabrication, Characterization, and Clinical Assessment of Ultrathin Skin-Conformable Tattoo Electrodes for ECG Monitoring

Uttam Kulhari, Sundareswaran Loganathan, Bidya Dhar Sahu, L. N. Sharma, Rutuja Vikhe, Mayur Krishna Das, Saurabh Kumar, A. P. Mishra, Sonal Masure, Errappagari Sreehari
article en
5 citations

Abstract

In recent years, there has been a surge in interest surrounding the advancement of gel-free, ultrathin, skin-conformable tattoo electrodes for continuous and extended monitoring of ECG signals. This development aims to mitigate the limitations associated with traditional electrodes. However, all of these results are limited to data from individual subjects. Hence, replicability is reduced by individual variability due to a small sample size, which may lead to inconclusive results. Consequently, the suitability of these outcomes for clinical validation has been inadequately investigated. In this study, an ultrathin, gel-free, skin-conformable PEDOT:PSS-based tattoo electrode was fabricated and characterized. A preclinical skin irritation test of the PEDOT:PSS-based tattoo electrode was performed before clinical assessment. Next, we accessed the performance of these tattoo electrodes involving 34 healthy volunteers and compared the ECG signals acquired from these ultrathin electrodes with those recorded by traditional Ag/AgCl electrodes. The fabricated tattoo electrode is approximately 10 μm thick and has a skin–electrode impedance of 72 KΩ at 50 Hz. The preclinical skin irritation study confirmed that the film of PEDOT:PSS is nontoxic, noncorrosive, and biocompatible with rabbit skin. In healthy volunteers, the data points from the sample population all cluster closely around the bias line, and we observed no significant systematic error associated with the ECG measurement. This PEDOT:PSS-based skin-conformal tattoo electrode retained its characteristics even after continuous wear for up to 24 h during routine activities, and the electrodes remained stable even after 60 days of storage. Altogether, our findings confirmed the suitability of these skin-conformal PEDOT:PSS-based tattoo electrodes for ECG monitoring.

ACS Applied Electronic MaterialsVol. 7(4)
All India Institute of Medical Sciences (IN)
Openalex Percentile: Top 9%
Advanced Sensor and Energy Harvesting Materials
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.