<b>Background/Objectives:</b> Effective communication in critical care is crucial, particularly with the constraints of Personal Protective Equipment (PPE). This study aimed to evaluate speech intelligibility under varying conditions of distance, ambient noise, and PPE types in a simulated ICU. <b>Methodology:</b> A quasi-experimental design was used with 23 participants in 24 scenarios, combining three distances (1, 2, and 5 m), two noise levels (quiet and ICU-like), and four PPE types (no mask, surgical mask, N95, and PAPR). Speech intelligibility was assessed by positioning the subjects at varying distances while playing phonetically balanced words through a playback device equipped with the different PPE being tested. The evaluation was conducted under two sound conditions (25 dB(A) and 45 dB(A)). The percentage of correct responses by the subjects to the perceived sounds was determined as a measure of intelligibility. The relation between variables was analyzed using the Wilcoxon Test and the Friedman Test. <b>Results:</b> Significant differences in word recognition were observed across conditions. Ambient noise reduced intelligibility, with recognition percentages significantly lowering in noisy environments. PPE type also influenced comprehension, with PAPR posing the greatest challenge. Friedman's test showed that increasing distance significantly decreased recognition accuracy. Distances beyond two meters negatively impacted intelligibility across all devices tested. <b>Conclusions:</b> In noisy conditions (>45 dB(A)), a combination of distances greater than two meters and PPE use reduced intelligibility by over 40%, potentially compromising patient safety. The use of communication aids, such as visual cues or alternative speech devices, is recommended, particularly with PAPRs, to enhance comprehension and ensure effective communication between healthcare providers and patients.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-02-12
DOI
https://doi.org/10.3390/healthcare13040398
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Distance, Noise, and Personal Respiratory Protective Equipment on Speech Comprehension in Simulated Critical Care Setting

Andrés Rojo‐Rojo, Gloria María Muñoz-Rubio, Juan Manuel Cánovas-Pallarés, José Eugenio Martínez-Abril et al.
Healthcare
Noise Effects and Management
article

Effects of Distance, Noise, and Personal Respiratory Protective Equipment on Speech Comprehension in Simulated Critical Care Setting

Andrés Rojo‐Rojo, Gloria María Muñoz-Rubio, Juan Manuel Cánovas-Pallarés, José Eugenio Martínez-Abril, Paloma Iniesta-Cortés
article en

Abstract

<b>Background/Objectives:</b> Effective communication in critical care is crucial, particularly with the constraints of Personal Protective Equipment (PPE). This study aimed to evaluate speech intelligibility under varying conditions of distance, ambient noise, and PPE types in a simulated ICU. <b>Methodology:</b> A quasi-experimental design was used with 23 participants in 24 scenarios, combining three distances (1, 2, and 5 m), two noise levels (quiet and ICU-like), and four PPE types (no mask, surgical mask, N95, and PAPR). Speech intelligibility was assessed by positioning the subjects at varying distances while playing phonetically balanced words through a playback device equipped with the different PPE being tested. The evaluation was conducted under two sound conditions (25 dB(A) and 45 dB(A)). The percentage of correct responses by the subjects to the perceived sounds was determined as a measure of intelligibility. The relation between variables was analyzed using the Wilcoxon Test and the Friedman Test. <b>Results:</b> Significant differences in word recognition were observed across conditions. Ambient noise reduced intelligibility, with recognition percentages significantly lowering in noisy environments. PPE type also influenced comprehension, with PAPR posing the greatest challenge. Friedman's test showed that increasing distance significantly decreased recognition accuracy. Distances beyond two meters negatively impacted intelligibility across all devices tested. <b>Conclusions:</b> In noisy conditions (>45 dB(A)), a combination of distances greater than two meters and PPE use reduced intelligibility by over 40%, potentially compromising patient safety. The use of communication aids, such as visual cues or alternative speech devices, is recommended, particularly with PAPRs, to enhance comprehension and ensure effective communication between healthcare providers and patients.

HealthcareVol. 13(4)
Hospital Universitario Virgen de la Arrixaca (ES), Universidad Católica de Murcia (ES), Universidad de Murcia (ES)
Openalex Percentile: Top 96%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.