Photobiomodulation LED Devices for Home Use: Design, Function and Potential: A Pilot Study

<b>Background/Objectives</b>: Many commercial light-emitting diode (LED) devices are available for consumer home usage. The performance characteristics in respect to the dosimetry of many of the devices, currently on direct sale to the public, have not been subject to formal appraisal. In order to 'bridge the gap' between the evidence-based photobiomodulation therapy (PBMT) community and other interested parties, an evaluation is made of a selection of torch type hand-held LED PBMT products currently available for home use. <b>Methods</b>: Five randomly chosen intra-oral and hand-held LED PBMT devices were selected. The optical delivery parameters of the devices were measured, including the beam divergence angle, surface area exposure as well as the output power at the level of the LEDs. The surface and sub-surface temperature changes in porcine tissue samples were assessed under standardised conditions. The manufacturer's patient instructions were correlated to the measured optical parameters. Calculations were made of irradiance and surface radiant exposure. Consumer satisfaction ratings and feedback data were collated, and a relevant statistical analysis conducted. <b>Results</b>: The results were heterogeneous with a wide range of applied wavelengths, output power and irradiance. Power output stability was variable, and, together with a wide beam divergence angle of 74°, the manufacturer's directions for dosimetry were found to be inconsistent with an accurate dose delivery. <b>Conclusions</b>: The manufacturer's proposed dosimetry fails to consider the relevance of the beam divergence angle and optical attenuation in view of the scatter and absorption. Appropriate instructions on how best to gain and optimise an acceptable clinical outcome were inconsistent with an evidence-based approach. Subject to validation by well-planned clinical trials, the concept of home PBMT may open interesting new therapeutic approaches.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-02-10
DOI
https://doi.org/10.3390/dj13020076
Citations
3
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photobiomodulation LED Devices for Home Use: Design, Function and Potential: A Pilot Study

Omar Hamadah, Josep Arnabat‐Domínguez, Mark Cronshaw, Martin Grootveld et al.
3 citations
Dentistry Journal
Laser Applications in Dentistry and Medicine
4.08
article

Photobiomodulation LED Devices for Home Use: Design, Function and Potential: A Pilot Study

Omar Hamadah, Josep Arnabat‐Domínguez, Mark Cronshaw, Martin Grootveld, Steven Parker
article en
3 citations

Abstract

<b>Background/Objectives</b>: Many commercial light-emitting diode (LED) devices are available for consumer home usage. The performance characteristics in respect to the dosimetry of many of the devices, currently on direct sale to the public, have not been subject to formal appraisal. In order to 'bridge the gap' between the evidence-based photobiomodulation therapy (PBMT) community and other interested parties, an evaluation is made of a selection of torch type hand-held LED PBMT products currently available for home use. <b>Methods</b>: Five randomly chosen intra-oral and hand-held LED PBMT devices were selected. The optical delivery parameters of the devices were measured, including the beam divergence angle, surface area exposure as well as the output power at the level of the LEDs. The surface and sub-surface temperature changes in porcine tissue samples were assessed under standardised conditions. The manufacturer's patient instructions were correlated to the measured optical parameters. Calculations were made of irradiance and surface radiant exposure. Consumer satisfaction ratings and feedback data were collated, and a relevant statistical analysis conducted. <b>Results</b>: The results were heterogeneous with a wide range of applied wavelengths, output power and irradiance. Power output stability was variable, and, together with a wide beam divergence angle of 74°, the manufacturer's directions for dosimetry were found to be inconsistent with an accurate dose delivery. <b>Conclusions</b>: The manufacturer's proposed dosimetry fails to consider the relevance of the beam divergence angle and optical attenuation in view of the scatter and absorption. Appropriate instructions on how best to gain and optimise an acceptable clinical outcome were inconsistent with an evidence-based approach. Subject to validation by well-planned clinical trials, the concept of home PBMT may open interesting new therapeutic approaches.

Dentistry JournalVol. 13(2)
De Montfort University (GB), Universitat de Barcelona (ES), Damascus University (SY)
Openalex Percentile: Top 8%
Laser Applications in Dentistry and Medicine
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.