Removal of the antidepressants bupropion and sertraline from aqueous solutions by using graphene oxide: A complete adsorption/desorption evaluation for single-component and binary mixtures

• GO proved to be highly efficient for the removal of bupropion and sertraline. • The adsorption process for both antidepressants was endothermic and spontaneous. • 4 kinetic and 10 isothermal models were tested. • GO exhibited a higher adsorption capacity for sertraline of 147.88 mg/g. • Single and binary pharmaceutical solutions were studied in different ratios. Graphene oxide, a material with exceptional adsorption properties, was employed for the removal of two antidepressants, sertraline and bupropion, from aqueous solutions. Batch adsorption experiments were conducted, under various conditions, to determine the optimal parameters for efficient removal. Equilibrium was met at 3 h, at pH 4 for 1 g/L of dosage, while a removal of 86 % and 98 % was achieved for bupropion and sertraline, respectively. According to Langmuir model, adsorption capacities of 147.88 mg/g and 67.35 mg/g were achieved at 25 °C for sertraline and bupropion, respectively. Thermodynamic analyses showed that the adsorption of both drugs was endothermic and spontaneous. The binary adsorption studies were performed in different ratios and revealed a higher affinity for sertraline, where a removal efficiency of > 90 % was maintained. The stability of the adsorbent under varying pH conditions was tested and showed higher stability at neutral conditions. Comprehensive material characterizations, including Fourier-transform infrared spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Brunauer–Emmett–Teller (BET) surface area analysis, X-ray diffraction (XRD), and pH at the point of zero charge (pHpzc) were performed. These findings demonstrate the potential of graphene oxide as an efficient adsorbent for the removal of pharmaceuticals from wastewater.

Authors

Institutions

Publication Details

Journal
Journal of Molecular Liquids
Published
2025-02-12
DOI
https://doi.org/10.1016/j.molliq.2025.127147
Citations
7
Primary Topic
Pharmacological Effects and Toxicity Studies
Type
article
Field-Weighted Citation Impact
24.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Removal of the antidepressants bupropion and sertraline from aqueous solutions by using graphene oxide: A complete adsorption/desorption evaluation for single-component and binary mixtures

Dimitrios Ν. Bikiaris, Εleni Εvgenidou, Αnastasia Koltsakidou, Dimitra A. Lambropoulou et al.
7 citations
Journal of Molecular Liquids
Pharmacological Effects and Toxicity Studies
24.46
article

Removal of the antidepressants bupropion and sertraline from aqueous solutions by using graphene oxide: A complete adsorption/desorption evaluation for single-component and binary mixtures

Dimitrios Ν. Bikiaris, Εleni Εvgenidou, Αnastasia Koltsakidou, Dimitra A. Lambropoulou, George Z. Kyzas, Konstantinos N. Maroulas
article en
7 citations

Abstract

• GO proved to be highly efficient for the removal of bupropion and sertraline. • The adsorption process for both antidepressants was endothermic and spontaneous. • 4 kinetic and 10 isothermal models were tested. • GO exhibited a higher adsorption capacity for sertraline of 147.88 mg/g. • Single and binary pharmaceutical solutions were studied in different ratios. Graphene oxide, a material with exceptional adsorption properties, was employed for the removal of two antidepressants, sertraline and bupropion, from aqueous solutions. Batch adsorption experiments were conducted, under various conditions, to determine the optimal parameters for efficient removal. Equilibrium was met at 3 h, at pH 4 for 1 g/L of dosage, while a removal of 86 % and 98 % was achieved for bupropion and sertraline, respectively. According to Langmuir model, adsorption capacities of 147.88 mg/g and 67.35 mg/g were achieved at 25 °C for sertraline and bupropion, respectively. Thermodynamic analyses showed that the adsorption of both drugs was endothermic and spontaneous. The binary adsorption studies were performed in different ratios and revealed a higher affinity for sertraline, where a removal efficiency of > 90 % was maintained. The stability of the adsorbent under varying pH conditions was tested and showed higher stability at neutral conditions. Comprehensive material characterizations, including Fourier-transform infrared spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Brunauer–Emmett–Teller (BET) surface area analysis, X-ray diffraction (XRD), and pH at the point of zero charge (pHpzc) were performed. These findings demonstrate the potential of graphene oxide as an efficient adsorbent for the removal of pharmaceuticals from wastewater.

Journal of Molecular LiquidsVol. 424
Democritus University of Thrace (GR), Aristotle University of Thessaloniki (GR), Centre for Research and Technology Hellas (GR)
Clean water and sanitation
Openalex Percentile: Top 0%
Pharmacological Effects and Toxicity Studies
24.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.