A Novel Synchronous Time Error Correction Method for Distribution Network Equipment

In this paper, a novel synchronous time error correction method is proposed for the distribution network equipment. According to the principle of time synchronization of distribution network equipment, the time synchronization error is analyzed between the station concentrator equipment and the distribution network equipment. Considering the influence of the uncertainty of the communication delay between the station concentrator and the distribution network equipment, the synchronization time of the distribution network equipment is employed to establish the time synchronization error matrix between each equipment. For filtering out the abnormal data of the error matrix, the multi-dimensional scaling (MDS) method and local outlier factor (LOF) method are utilized. Then, a corrected time synchronization error matrix is built without the corresponding data of the abnormal equipment. According to the corrected error matrix, the synchronization error of distribution network equipment is calculated, and the corrected synchronization time is defined for distribution network equipment. Simulation shows that the proposed method can achieve the filtering of abnormal data of synchronization error and reduce the impact of communication delay uncertainty on time synchronization.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/sgee64306.2024.10865970
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Synchronous Time Error Correction Method for Distribution Network Equipment

Weijie Zeng, Mouhai Liu, Zhi Wang, Jing Yang
Power Systems and Technologies
article

A Novel Synchronous Time Error Correction Method for Distribution Network Equipment

Weijie Zeng, Mouhai Liu, Zhi Wang, Jing Yang
article en

Abstract

In this paper, a novel synchronous time error correction method is proposed for the distribution network equipment. According to the principle of time synchronization of distribution network equipment, the time synchronization error is analyzed between the station concentrator equipment and the distribution network equipment. Considering the influence of the uncertainty of the communication delay between the station concentrator and the distribution network equipment, the synchronization time of the distribution network equipment is employed to establish the time synchronization error matrix between each equipment. For filtering out the abnormal data of the error matrix, the multi-dimensional scaling (MDS) method and local outlier factor (LOF) method are utilized. Then, a corrected time synchronization error matrix is built without the corresponding data of the abnormal equipment. According to the corrected error matrix, the synchronization error of distribution network equipment is calculated, and the corrected synchronization time is defined for distribution network equipment. Simulation shows that the proposed method can achieve the filtering of abnormal data of synchronization error and reduce the impact of communication delay uncertainty on time synchronization.

Hunan Xiangdian Test Research Institute (China) (CN)
Openalex Percentile: Top 75%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.