Near-Field Sensing of mmWave XL-MIMO Systems through Joint Parabolic Interpolation and Barycenter Calibration

The pursuit of higher data rates in next-generation mobile communications necessitates the use of higher frequency bands and larger antenna arrays. These shifts will extend the Rayleigh distance, resulting in near-field effects, where traditional far-field algorithms for source sensing yield considerable errors. Moreover, near-field spatial spectrum estimation algorithms require multi-dimensional spectral peak searches, which lead to high computational complexity and necessitate a trade-off between sensing accuracy and real-time performance. To address these issues, we propose the joint parabolic interpolation and barycenter calibration (PI-BC) algorithm, a calibration method for near-field spectral peak searches. The joint PI-BC algorithm significantly boosts sensing accuracy while maintaining low computational complexity, thus providing a real-time, efficient solution for near-field sensing.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/icsidp62679.2024.10869216
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Near-Field Sensing of mmWave XL-MIMO Systems through Joint Parabolic Interpolation and Barycenter Calibration

Mugen Peng, Zhaoqi Wang, Xiqing Liu, Baoyue Zhao
Electromagnetic Compatibility and Measurements
article

Near-Field Sensing of mmWave XL-MIMO Systems through Joint Parabolic Interpolation and Barycenter Calibration

Mugen Peng, Zhaoqi Wang, Xiqing Liu, Baoyue Zhao
article en

Abstract

The pursuit of higher data rates in next-generation mobile communications necessitates the use of higher frequency bands and larger antenna arrays. These shifts will extend the Rayleigh distance, resulting in near-field effects, where traditional far-field algorithms for source sensing yield considerable errors. Moreover, near-field spatial spectrum estimation algorithms require multi-dimensional spectral peak searches, which lead to high computational complexity and necessitate a trade-off between sensing accuracy and real-time performance. To address these issues, we propose the joint parabolic interpolation and barycenter calibration (PI-BC) algorithm, a calibration method for near-field spectral peak searches. The joint PI-BC algorithm significantly boosts sensing accuracy while maintaining low computational complexity, thus providing a real-time, efficient solution for near-field sensing.

Beijing University of Posts and Telecommunications (CN)
National Natural Science Foundation of China, Research and Development
Affordable and clean energy
Openalex Percentile: Top 75%
Electromagnetic Compatibility and Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.