Energy-saving optimization of precision air conditioning system in data center based on E-WOA algorithm

In China, with the rapid development of information technology, the number of data centers is constantly increasing. Massive data transmission and storage, as well as inefficient precision air conditioning systems, result in significant power consumption in data centers. This article takes data centers as the research object and establishes a model for the energy consumption of various equipment in air conditioning systems based on the working principle of air conditioning. Under the condition of meeting indoor cooling load requirements, taking the total energy consumption of the air conditioner as the objective function and the supply air temperature, chilled water supply temperature, and chilled water return temperature as decision variables, the total energy consumption of precision air conditioning is minimized. The enhanced whale optimization algorithm is used to obtain the optimal solution of parameters that meet the objective function and constraint conditions and optimize the parameters of the precision air conditioning system. The total energy cost of the optimized precision air conditioner has decreased significantly, hourly energy saving is 9.2%, effectively reducing the PUE of the data center.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icemce64157.2024.10862428
Citations
1
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy-saving optimization of precision air conditioning system in data center based on E-WOA algorithm

Ruping Shao, Chunyang Jiang, Jing Yang
1 citations
Advanced Sensor and Control Systems
0.33
article

Energy-saving optimization of precision air conditioning system in data center based on E-WOA algorithm

Ruping Shao, Chunyang Jiang, Jing Yang
article en
1 citations

Abstract

In China, with the rapid development of information technology, the number of data centers is constantly increasing. Massive data transmission and storage, as well as inefficient precision air conditioning systems, result in significant power consumption in data centers. This article takes data centers as the research object and establishes a model for the energy consumption of various equipment in air conditioning systems based on the working principle of air conditioning. Under the condition of meeting indoor cooling load requirements, taking the total energy consumption of the air conditioner as the objective function and the supply air temperature, chilled water supply temperature, and chilled water return temperature as decision variables, the total energy consumption of precision air conditioning is minimized. The enhanced whale optimization algorithm is used to obtain the optimal solution of parameters that meet the objective function and constraint conditions and optimize the parameters of the precision air conditioning system. The total energy cost of the optimized precision air conditioner has decreased significantly, hourly energy saving is 9.2%, effectively reducing the PUE of the data center.

Nanjing Tech University (CN)
Affordable and clean energy
Openalex Percentile: Top 37%
Advanced Sensor and Control Systems
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Energy-saving optimization of precision air conditioning system in data center based on E-WOA algorithm — Ruping Shao, Chunyang Jiang, et al. · (2024) | TGRS Research Map | TGRS