Research on current transformer error verification system based on digital comparison method

In order to meet the new demand for measuring wide range, mixed $\mathrm{AC} / \mathrm{DC}$, injected harmonics and other wide dynamic current signals of bidirectional power flow after the integration of wind and solar new energy, research on current transformer technology for complex signal measurement is increasing. However, there is currently no relevant research report on error verification of current transformers for wide dynamic measurement. On the basis of traditional current transformer calibration technology, this article designs a current transformer error calibration system based on digital comparison method. The principle of digital comparison method technology is analyzed, and a Nutall self multiplication convolution window double spectral line interpolation algorithm is proposed. The amplitude and phase formulas are derived and corrected. Simulation and experimental data show that the measurement error of the algorithm is better than $10-6$ values, and the measurement accuracy of the verification system is better than ± 0.1%, providing a new idea for error verification of current transformers for complex signal measurement.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icemce64157.2024.10862493
Citations
1
Primary Topic
Engineering and Test Systems
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on current transformer error verification system based on digital comparison method

Xiaofei Fan, Xinglin Guo, Shihong Yin, Baoshuai Wang
1 citations
Engineering and Test Systems
0.33
article

Research on current transformer error verification system based on digital comparison method

Xiaofei Fan, Xinglin Guo, Shihong Yin, Baoshuai Wang
article en
1 citations

Abstract

In order to meet the new demand for measuring wide range, mixed $\mathrm{AC} / \mathrm{DC}$, injected harmonics and other wide dynamic current signals of bidirectional power flow after the integration of wind and solar new energy, research on current transformer technology for complex signal measurement is increasing. However, there is currently no relevant research report on error verification of current transformers for wide dynamic measurement. On the basis of traditional current transformer calibration technology, this article designs a current transformer error calibration system based on digital comparison method. The principle of digital comparison method technology is analyzed, and a Nutall self multiplication convolution window double spectral line interpolation algorithm is proposed. The amplitude and phase formulas are derived and corrected. Simulation and experimental data show that the measurement error of the algorithm is better than $10-6$ values, and the measurement accuracy of the verification system is better than ± 0.1%, providing a new idea for error verification of current transformers for complex signal measurement.

Shenzhen Stock Exchange (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 37%
Engineering and Test Systems
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.