Design and simulation of hydraulic self-driven flood control gate based on ANSYS

The traditional gate can not use the natural conditions to achieve flood control function, in the flood comes by relying on human operation, can not carry out timely flood control operation. This paper proposes a hydraulic self-drive flood control gate, which mainly includes hydraulic dynamic drive mechanism and hydraulic drive mechanism. Use SolidWorks 3 D modeling software to establish its 3 D model, with the overall length of 6.5 m, the width of 1.5 m and the height of 4.5 m. And the secondary protection function is realized through the hydraulic drive mechanism. The parameters of the gate are set, and the specific design parameters of the water tank and hydraulic cylinder are obtained through the theoretical analysis of the two mechanisms. Ansys simulation software is used for dynamic analysis and mode analysis, show that the maximum stress of the gate is 8.84 Mpa and the maximum deformation is 0.186 mm, which meets the requirements of gate design strength and stiffness of the gate. Mode analysis simulation results show that the minimum vibration frequency of the gate is 34.588 Hz, greater than the maximum pulse frequency of water flow is 20 Hz, which almost does not resonate with the flood.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icemce64157.2024.10862129
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and simulation of hydraulic self-driven flood control gate based on ANSYS

Jing Bai, Chen Lv, Danyang Liu, Chenyang Zhou et al.
Advanced Sensor and Control Systems
article

Design and simulation of hydraulic self-driven flood control gate based on ANSYS

Jing Bai, Chen Lv, Danyang Liu, Chenyang Zhou, Shengjie Zhao
article en

Abstract

The traditional gate can not use the natural conditions to achieve flood control function, in the flood comes by relying on human operation, can not carry out timely flood control operation. This paper proposes a hydraulic self-drive flood control gate, which mainly includes hydraulic dynamic drive mechanism and hydraulic drive mechanism. Use SolidWorks 3 D modeling software to establish its 3 D model, with the overall length of 6.5 m, the width of 1.5 m and the height of 4.5 m. And the secondary protection function is realized through the hydraulic drive mechanism. The parameters of the gate are set, and the specific design parameters of the water tank and hydraulic cylinder are obtained through the theoretical analysis of the two mechanisms. Ansys simulation software is used for dynamic analysis and mode analysis, show that the maximum stress of the gate is 8.84 Mpa and the maximum deformation is 0.186 mm, which meets the requirements of gate design strength and stiffness of the gate. Mode analysis simulation results show that the minimum vibration frequency of the gate is 34.588 Hz, greater than the maximum pulse frequency of water flow is 20 Hz, which almost does not resonate with the flood.

Xi'an Shiyou University (CN)
Climate action
Openalex Percentile: Top 67%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.