Study on the circuit resistance and characteristics of poor contact in high-voltage cable lead seals

Defects causing electrical contact issues in high-voltage cable end seals occur frequently due to poor conductor crimping, loose connections, or solder joint failures. Inspection methods based on infrared detection technology and circuit resistance testing are important for preventing such defects. To fully understand the physical mechanisms of contact failure during the operation of high-voltage cable end seals, this study establishes a simulation model of circuit resistance using finite element analysis software. It analyzes changes in circuit resistance with different volumes of oxidation and fracture in the lead seal and conducts electro-thermal coupling simulations. The results indicate that as the oxidation and fracture volumes in the lead seal increase, the circuit resistance caused by oxidation changes at the milliohm level, making it difficult to detect with infrared technology. In contrast, resistance due to lead seal fractures can rise to the ohm level, potentially exceeding the thermal tolerance of the cable’s XLPE layer, leading to insulation damage.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icemce64157.2024.10862134
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the circuit resistance and characteristics of poor contact in high-voltage cable lead seals

Chengjun Huang, Ting Ye
Electrical Contact Performance and Analysis
article

Study on the circuit resistance and characteristics of poor contact in high-voltage cable lead seals

Chengjun Huang, Ting Ye
article en

Abstract

Defects causing electrical contact issues in high-voltage cable end seals occur frequently due to poor conductor crimping, loose connections, or solder joint failures. Inspection methods based on infrared detection technology and circuit resistance testing are important for preventing such defects. To fully understand the physical mechanisms of contact failure during the operation of high-voltage cable end seals, this study establishes a simulation model of circuit resistance using finite element analysis software. It analyzes changes in circuit resistance with different volumes of oxidation and fracture in the lead seal and conducts electro-thermal coupling simulations. The results indicate that as the oxidation and fracture volumes in the lead seal increase, the circuit resistance caused by oxidation changes at the milliohm level, making it difficult to detect with infrared technology. In contrast, resistance due to lead seal fractures can rise to the ohm level, potentially exceeding the thermal tolerance of the cable’s XLPE layer, leading to insulation damage.

Shanghai Jiao Tong University (CN), Shanghai Electric (China) (CN)
No poverty
Openalex Percentile: Top 73%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.