Design and experimental study of integrated multidimensional force measuring tool-holder

INTRODUCTION: In view of the force testing process in milling, this paper proposes a multi-dimensional force testing tool-holder based on HSK 63A tool holder, beam force sensor and strain gauge bridge. METHODS: In response to the structural stifness of the force measuring tool-holder, simulation driven optimization was carried out. On this basis, the construction of the force measuring tool-holder detection platform was completed. Finally, this article conducted experimental research on static calibration and dynamic testing of the force measuring tool holder. RESULTS: The results show that compared with the reference force measuring instrument, the measurement errors of axial force, radial resultant force, and torque are controlled within $9.5 \%, 8.7 \%$, and 6.7%, respectively.

Authors

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icemce64157.2024.10862344
Primary Topic
Advanced machining processes and optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and experimental study of integrated multidimensional force measuring tool-holder

Yonghao Qian, Fei Long
Advanced machining processes and optimization
article

Design and experimental study of integrated multidimensional force measuring tool-holder

Yonghao Qian, Fei Long
article en

Abstract

INTRODUCTION: In view of the force testing process in milling, this paper proposes a multi-dimensional force testing tool-holder based on HSK 63A tool holder, beam force sensor and strain gauge bridge. METHODS: In response to the structural stifness of the force measuring tool-holder, simulation driven optimization was carried out. On this basis, the construction of the force measuring tool-holder detection platform was completed. Finally, this article conducted experimental research on static calibration and dynamic testing of the force measuring tool holder. RESULTS: The results show that compared with the reference force measuring instrument, the measurement errors of axial force, radial resultant force, and torque are controlled within $9.5 \%, 8.7 \%$, and 6.7%, respectively.

Openalex Percentile: Top 73%
Advanced machining processes and optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.