Near-Infrared Mobile Cloud OA-ICOS Sensor System for Atmospheric Carbon Dioxide Monitoring

Based on near-infrared off-axis integrated cavity output spectroscopy (OA-ICOS), a portable carbon dioxide (CO<sub>2</sub>) sensor system capable of atmosphere monitoring is proposed by targeting the CO<sub>2</sub> absorption lines at 2.004 μm. To address the comprehensive issues of complex light-adjustment structures, poor sealing, and slow gas replacement, an effective optimization scheme is introduced, combining fluid dynamics to produce a stable optical resonant cavity with an optical path length of 891 m and a physical length of 30 cm. The sensor system boasts a wide dynamic range of 0.011-800 parts per million (ppm), with a limit of detection (LoD) of 11 parts per billion (ppb) at an averaging time of 0.5 s. To address the issues of long monitoring time and cumbersome data supervision, a cloud monitoring system was developed based on a master control module, a cloud server, and a portable monitoring terminal. Field mobile monitoring of urban CO<sub>2</sub> was conducted over a large area in Changchun city, along with a 7-day fixed-point detection on the campus of Jilin University, verifying the reliability and application potential of the mobile CO<sub>2</sub> monitoring system in field applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-12
DOI
https://doi.org/10.1021/acs.analchem.4c05644
Citations
8
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
8.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Near-Infrared Mobile Cloud OA-ICOS Sensor System for Atmospheric Carbon Dioxide Monitoring

Kaiyuan Zheng, Fang Song, Zhiyong Chang, Chuantao Zheng et al.
8 citations
Analytical Chemistry
Atmospheric and Environmental Gas Dynamics
8.84
article

Near-Infrared Mobile Cloud OA-ICOS Sensor System for Atmospheric Carbon Dioxide Monitoring

Kaiyuan Zheng, Fang Song, Zhiyong Chang, Chuantao Zheng, Lei Zhang, Ying Hua, Yishen Zhou
article en
8 citations

Abstract

Based on near-infrared off-axis integrated cavity output spectroscopy (OA-ICOS), a portable carbon dioxide (CO<sub>2</sub>) sensor system capable of atmosphere monitoring is proposed by targeting the CO<sub>2</sub> absorption lines at 2.004 μm. To address the comprehensive issues of complex light-adjustment structures, poor sealing, and slow gas replacement, an effective optimization scheme is introduced, combining fluid dynamics to produce a stable optical resonant cavity with an optical path length of 891 m and a physical length of 30 cm. The sensor system boasts a wide dynamic range of 0.011-800 parts per million (ppm), with a limit of detection (LoD) of 11 parts per billion (ppb) at an averaging time of 0.5 s. To address the issues of long monitoring time and cumbersome data supervision, a cloud monitoring system was developed based on a master control module, a cloud server, and a portable monitoring terminal. Field mobile monitoring of urban CO<sub>2</sub> was conducted over a large area in Changchun city, along with a 7-day fixed-point detection on the campus of Jilin University, verifying the reliability and application potential of the mobile CO<sub>2</sub> monitoring system in field applications.

Analytical ChemistryVol. 97(7)
Hong Kong Polytechnic University (HK), Jilin University (CN), State Key Laboratory on Integrated Optoelectronics (CN), Jilin Medical University (CN)
National Natural Science Foundation of China, People's Government of Jilin Province, Education Department of Jilin Province, National Key Research and Development Program of China
Climate action
Openalex Percentile: Top 2%
Atmospheric and Environmental Gas Dynamics
8.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.