Carotid Artery Corrected Flow Time Measured by Wearable Doppler Ultrasound Detects Stroke Volume Change Measured by Transesophageal Echocardiography After Coronary Artery Bypass Grafting

Background: As a measure of preload responsiveness (PR), change in carotid artery corrected flow time (ccFTΔ) is a surrogate for change in stroke volume (SVΔ). However, the optimal threshold and accuracy of ccFTΔ to detect SVΔ are inconsistent in previous reports. Research Question: Does ccFTΔ from a wireless, wearable Doppler ultrasound accurately detect a 10% SVΔ measured by transesophageal echocardiography? Study Design and Methods: This was a prospective, single-center study of adult patients after elective coronary artery bypass grafting. PR was defined as ≥ 10% augmentation in transesophageal echocardiography left ventricular outflow tract velocity time integral (as a surrogate for SVΔ) during Trendelenburg positioning. Synchronous carotid Doppler imaging was captured by a wireless, wearable Doppler ultrasound. The optimal ccFTΔ threshold to detect PR, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Linear correlation between ccFTΔ and SVΔ was assessed by Pearson correlation coefficient. We also evaluated the effect of the number of consecutively averaged cardiac cycles on ccFTΔ accuracy. Results: This analysis included 30 patients; 7 patients showed a ≥ 10% SVΔ during Trendelenburg positioning. The optimal ccFTΔ thresholds were +6.6 ms or 2.2% with sensitivities of 100%, specificities of 70%, and AUCs of 0.89 and 0.88, respectively. A strong, linear correlation between ccFTΔ and SVΔ was found (r = 0.70; P < .001). The mean AUC increased from 0.68 to 0.87 when using 1 vs 20 consecutively averaged cardiac cycles. Interpretation: After cardiopulmonary bypass, ccFTΔ measured by wireless, wearable ultrasound detected SVΔ during Trendelenburg positioning with high accuracy. The AUC improved as a function of consecutively averaged cardiac cycles. As a surrogate for preload-induced SVΔ, ccFTΔ can direct fluid therapy in the postoperative period.

Authors

Publication Details

Journal
CHEST Critical Care
Published
2025-02-12
DOI
https://doi.org/10.1016/j.chstcc.2025.100138
Citations
6
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
8.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carotid Artery Corrected Flow Time Measured by Wearable Doppler Ultrasound Detects Stroke Volume Change Measured by Transesophageal Echocardiography After Coronary Artery Bypass Grafting

Mai Elfarnawany, Chelsea E. Munding, Isabel Kerrebijn, Rony Atoui et al.
6 citations
CHEST Critical Care
Cardiovascular Health and Disease Prevention
8.33
article

Carotid Artery Corrected Flow Time Measured by Wearable Doppler Ultrasound Detects Stroke Volume Change Measured by Transesophageal Echocardiography After Coronary Artery Bypass Grafting

Mai Elfarnawany, Chelsea E. Munding, Isabel Kerrebijn, Rony Atoui, Jon‐Émile S. Kenny, Bhanu Nalla, Joseph Karl Eibl, Sarah Atwi, Geoffrey D. Clarke, Tracy Savery, Meredith Knott, Andrew M. Eibl BComm
article en
6 citations

Abstract

Background: As a measure of preload responsiveness (PR), change in carotid artery corrected flow time (ccFTΔ) is a surrogate for change in stroke volume (SVΔ). However, the optimal threshold and accuracy of ccFTΔ to detect SVΔ are inconsistent in previous reports. Research Question: Does ccFTΔ from a wireless, wearable Doppler ultrasound accurately detect a 10% SVΔ measured by transesophageal echocardiography? Study Design and Methods: This was a prospective, single-center study of adult patients after elective coronary artery bypass grafting. PR was defined as ≥ 10% augmentation in transesophageal echocardiography left ventricular outflow tract velocity time integral (as a surrogate for SVΔ) during Trendelenburg positioning. Synchronous carotid Doppler imaging was captured by a wireless, wearable Doppler ultrasound. The optimal ccFTΔ threshold to detect PR, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Linear correlation between ccFTΔ and SVΔ was assessed by Pearson correlation coefficient. We also evaluated the effect of the number of consecutively averaged cardiac cycles on ccFTΔ accuracy. Results: This analysis included 30 patients; 7 patients showed a ≥ 10% SVΔ during Trendelenburg positioning. The optimal ccFTΔ thresholds were +6.6 ms or 2.2% with sensitivities of 100%, specificities of 70%, and AUCs of 0.89 and 0.88, respectively. A strong, linear correlation between ccFTΔ and SVΔ was found (r = 0.70; P < .001). The mean AUC increased from 0.68 to 0.87 when using 1 vs 20 consecutively averaged cardiac cycles. Interpretation: After cardiopulmonary bypass, ccFTΔ measured by wireless, wearable ultrasound detected SVΔ during Trendelenburg positioning with high accuracy. The AUC improved as a function of consecutively averaged cardiac cycles. As a surrogate for preload-induced SVΔ, ccFTΔ can direct fluid therapy in the postoperative period.

CHEST Critical CareVol. 3(2)
Northern Ontario Academic Medicine Association
Good health and well-being
Openalex Percentile: Top 2%
Cardiovascular Health and Disease Prevention
8.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.