Reduction of acoustic reverberation noise from therapeutic transducer for estimation of heat source distribution by acoustic radiation force imaging for high-intensity focused ultrasound treatment

Abstract High-intensity focused ultrasound (HIFU) is a noninvasive treatment that requires precise control of heat distribution to ensure safety and efficacy. Previous studies used a displacement measurement by acoustic radiation force (ARF) to predict the treated region before the treatment. However, measurement of displacement distribution immediately after the HIFU sonication is challenging due to interference from HIFU reverberation waves. In this study, three frequency filters—a high-pass filter, a combination of three notch filters, and a combination of high-pass and notch filters—were examined to reduce the HIFU reverberation components. In ex vivo experiments using chicken gizzard, the combination of high-pass and notch filters effectively attenuated noise at the fundamental (1 MHz), second harmonic (2 MHz), and third harmonic (3 MHz) frequencies, resulting in stable and accurate displacement measurements across a wide range of SNR conditions. These findings will contribute to improving the prediction accuracy of the treated region prior to the HIFU-based treatment.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-02-12
DOI
https://doi.org/10.35848/1347-4065/adb4fd
Citations
1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduction of acoustic reverberation noise from therapeutic transducer for estimation of heat source distribution by acoustic radiation force imaging for high-intensity focused ultrasound treatment

Kazuto Kodama, S. Yoshizawa, Shohei Mori
1 citations
Japanese Journal of Applied Physics
Ultrasound and Hyperthermia Applications
0.67
article

Reduction of acoustic reverberation noise from therapeutic transducer for estimation of heat source distribution by acoustic radiation force imaging for high-intensity focused ultrasound treatment

Kazuto Kodama, S. Yoshizawa, Shohei Mori
article en
1 citations

Abstract

Abstract High-intensity focused ultrasound (HIFU) is a noninvasive treatment that requires precise control of heat distribution to ensure safety and efficacy. Previous studies used a displacement measurement by acoustic radiation force (ARF) to predict the treated region before the treatment. However, measurement of displacement distribution immediately after the HIFU sonication is challenging due to interference from HIFU reverberation waves. In this study, three frequency filters—a high-pass filter, a combination of three notch filters, and a combination of high-pass and notch filters—were examined to reduce the HIFU reverberation components. In ex vivo experiments using chicken gizzard, the combination of high-pass and notch filters effectively attenuated noise at the fundamental (1 MHz), second harmonic (2 MHz), and third harmonic (3 MHz) frequencies, resulting in stable and accurate displacement measurements across a wide range of SNR conditions. These findings will contribute to improving the prediction accuracy of the treated region prior to the HIFU-based treatment.

Japanese Journal of Applied PhysicsVol. 64(3)
Tohoku University (JP), Tohoku University Hospital (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 35%
Ultrasound and Hyperthermia Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.