Evaluation of FeMnN alloy bioresorbable flow diverting stents in the rabbit abdominal aorta

Flow diverting stents are braided, metallic endoluminal devices widely used to treat intracranial aneurysms. Bioresorbable flow diverters (BRFDs) are gaining traction as the next generation of flow diverter technology. BRFDs aim to occlude and heal the aneurysm before safely dissolving into the body, mitigating or eliminating complications associated with the permanent presence of conventional flow diverters such as thromboembolism and stenosis. Additional putative advantages of a BRFD include a reduction in metal induced medical imaging artifacts, a restoration of physiological vasoreactivity, and allowing physicians to re-access the aneurysm if an additional procedure is required. In this current study, iron-manganese-nitrogen (FeMnN) alloy BRFDs and permanent control FDs composed of an industry standard Cobalt-Nickel-Chromium alloy were deployed in the rabbit aorta. MicroCT and SEM corrosion analysis determined the FeMnN wire volumes and cross-sectional areas had reduced approximately 85 % and 95 % after 3- and 6-months implantation duration, respectively. Histological analysis demonstrated the BRFDs exhibited suitable biocompatibility, with no cases of in-stent thrombosis, clinically significant stenosis, or adverse tissue responses observed. Immunohistochemistry revealed the neointimas surrounding the BRFDs featured a confluent endothelium covering several layers of smooth muscle cells, with macrophages adjacent to the device wires. The macrophages were able to penetrate the corrosion product and were observed transporting corrosion products away from the implant site. This current work provides primary <i>in vivo</i> corrosion and biocompatibility data to the field for FeMn alloys, which we feel will stimulate and inform the design of next-generation bioresorbable endovascular devices.

Authors

Institutions

Publication Details

Journal
Bioactive Materials
Published
2025-02-12
DOI
https://doi.org/10.1016/j.bioactmat.2025.01.039
Citations
2
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of FeMnN alloy bioresorbable flow diverting stents in the rabbit abdominal aorta

Ramanathan Kadirvel, Daying Dai, Roger J. Guillory, Cem Bilgin et al.
2 citations
Bioactive Materials
Aortic aneurysm repair treatments
3.04
article

Evaluation of FeMnN alloy bioresorbable flow diverting stents in the rabbit abdominal aorta

Ramanathan Kadirvel, Daying Dai, Roger J. Guillory, Cem Bilgin, Dan Dragomir‐Daescu, John M. Pederson, Alexander A Oliver, Andrew J. Vercnocke, Jonathan Cortese, Adam J. Griebel, Jeremy E. Schaffer, David F. Kallmes, Esref Alperen Bayraktar, Kent Carlson, Yong Hong Ding, Mitchell L. Connon, Sarah A. Erdahl
article en
2 citations

Abstract

Flow diverting stents are braided, metallic endoluminal devices widely used to treat intracranial aneurysms. Bioresorbable flow diverters (BRFDs) are gaining traction as the next generation of flow diverter technology. BRFDs aim to occlude and heal the aneurysm before safely dissolving into the body, mitigating or eliminating complications associated with the permanent presence of conventional flow diverters such as thromboembolism and stenosis. Additional putative advantages of a BRFD include a reduction in metal induced medical imaging artifacts, a restoration of physiological vasoreactivity, and allowing physicians to re-access the aneurysm if an additional procedure is required. In this current study, iron-manganese-nitrogen (FeMnN) alloy BRFDs and permanent control FDs composed of an industry standard Cobalt-Nickel-Chromium alloy were deployed in the rabbit aorta. MicroCT and SEM corrosion analysis determined the FeMnN wire volumes and cross-sectional areas had reduced approximately 85 % and 95 % after 3- and 6-months implantation duration, respectively. Histological analysis demonstrated the BRFDs exhibited suitable biocompatibility, with no cases of in-stent thrombosis, clinically significant stenosis, or adverse tissue responses observed. Immunohistochemistry revealed the neointimas surrounding the BRFDs featured a confluent endothelium covering several layers of smooth muscle cells, with macrophages adjacent to the device wires. The macrophages were able to penetrate the corrosion product and were observed transporting corrosion products away from the implant site. This current work provides primary <i>in vivo</i> corrosion and biocompatibility data to the field for FeMn alloys, which we feel will stimulate and inform the design of next-generation bioresorbable endovascular devices.

Bioactive MaterialsVol. 48
Mayo Clinic (US), Medical College of Wisconsin (US), Lakeside Labs (AT), FWRadiology (US), Mayo Clinic in Florida (US), Bicêtre Hospital (FR)
American Heart Association, National Institutes of Health, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 11%
Aortic aneurysm repair treatments
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.