HypE-GA based study on optimal design of standard floor facade windowing of high-rise office buildings facing energy saving in heating, cooling and lighting

The quantitative design on area and location of building façade's windows has a significant impact on interior light and heat environment, which is also very instructive for preliminary and remodeling design of buildings. However, previous studies paid more attention to the thermal insulation construction and shading based on design parameters from the perspective of designers, but neglected the fact that the geometric properties of the windows themselves are equally important for building energy efficiency. Secondly, the weak interactivity and algorithmic limitations of traditional simulation platforms prevent rapid access to ideal design strategies. Therefore, this paper takes the standard floor of a high-rise office building as the research object in cold region-Yantai, facing façade windowing design, the three building performance objectives of each office unit-Annual Cooling Energy Consumption (AC), Annual Heating Energy Consumption (AH) and Annual Lighting Energy Consumption (AL)-are simulated and single/multi-objective optimized by relying on Ladybug and Honeybee (LB + HB) platform and Hypervolume Estimation Genetic Algorithm (HypE-GA) to obtain the genome of Pareto-Window-to-Wall Ratio (WWR), Window Height (WH) and Sill Height (SH)-at the lowest of each performance objective in order to determine the most energy-efficient façade windowing expression. The results show that AH and AC, their sum of quantities remains stable, are main energy consumption sources of office buildings, while the change of AL is more likely to have an impact than the others' on Annual Totaling Energy Consumption (AT). The analysis points out that different windowing strategies can be adopted for different performance objectives. To reduce AC, priority is given to windowing on the east and north facade, with East Window-to-Wall Ratio (WWRE) at 0.2 ~ 0.3 and North Window-to-Wall Ratio (WWRN) at 0.3 ~ 0.5; to reduce AH, windows on the west and north facade should not be opened, and the remaining facades should be opened in small areas; to reduce AL, WWR> 0.7 is appropriate for each facade, and should be considered to matching a higher SH or WH; From AT, the average WWR in the single-objective and multi-objective optimization results are similar, so it is suggested that the WWR of each facade of office buildings in Yantai area is WWRE = 0.47, North South Window-to-Wall Ratio (WWRS) = 0.46, West Window-to-Wall Ratio (WWRW) = 0.18 and WWRN = 0.54. In addition, this paper proposes a method that can quickly find the Pareto optimal solution by clustering analysis on optimized results through Origin in multi-objective HypE-GA optimization study.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-02-12
DOI
https://doi.org/10.1371/journal.pone.0309817
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

HypE-GA based study on optimal design of standard floor facade windowing of high-rise office buildings facing energy saving in heating, cooling and lighting

Jieli Sui, W Zhang
1 citations
PLoS ONE
Building Energy and Comfort Optimization
1.01
article

HypE-GA based study on optimal design of standard floor facade windowing of high-rise office buildings facing energy saving in heating, cooling and lighting

Jieli Sui, W Zhang
article en
1 citations

Abstract

The quantitative design on area and location of building façade's windows has a significant impact on interior light and heat environment, which is also very instructive for preliminary and remodeling design of buildings. However, previous studies paid more attention to the thermal insulation construction and shading based on design parameters from the perspective of designers, but neglected the fact that the geometric properties of the windows themselves are equally important for building energy efficiency. Secondly, the weak interactivity and algorithmic limitations of traditional simulation platforms prevent rapid access to ideal design strategies. Therefore, this paper takes the standard floor of a high-rise office building as the research object in cold region-Yantai, facing façade windowing design, the three building performance objectives of each office unit-Annual Cooling Energy Consumption (AC), Annual Heating Energy Consumption (AH) and Annual Lighting Energy Consumption (AL)-are simulated and single/multi-objective optimized by relying on Ladybug and Honeybee (LB + HB) platform and Hypervolume Estimation Genetic Algorithm (HypE-GA) to obtain the genome of Pareto-Window-to-Wall Ratio (WWR), Window Height (WH) and Sill Height (SH)-at the lowest of each performance objective in order to determine the most energy-efficient façade windowing expression. The results show that AH and AC, their sum of quantities remains stable, are main energy consumption sources of office buildings, while the change of AL is more likely to have an impact than the others' on Annual Totaling Energy Consumption (AT). The analysis points out that different windowing strategies can be adopted for different performance objectives. To reduce AC, priority is given to windowing on the east and north facade, with East Window-to-Wall Ratio (WWRE) at 0.2 ~ 0.3 and North Window-to-Wall Ratio (WWRN) at 0.3 ~ 0.5; to reduce AH, windows on the west and north facade should not be opened, and the remaining facades should be opened in small areas; to reduce AL, WWR> 0.7 is appropriate for each facade, and should be considered to matching a higher SH or WH; From AT, the average WWR in the single-objective and multi-objective optimization results are similar, so it is suggested that the WWR of each facade of office buildings in Yantai area is WWRE = 0.47, North South Window-to-Wall Ratio (WWRS) = 0.46, West Window-to-Wall Ratio (WWRW) = 0.18 and WWRN = 0.54. In addition, this paper proposes a method that can quickly find the Pareto optimal solution by clustering analysis on optimized results through Origin in multi-objective HypE-GA optimization study.

PLoS ONEVol. 20(2)
Yantai University (CN)
Shandong Office of Philosophy and Social Science
Affordable and clean energy
Openalex Percentile: Top 28%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.