Study on the Causes and Countermeasures of High Lightning Trip-Out Rate on Electric Transmission Lines

Trip faults are obviously increased by frequent lightning strikes, and increasing lightning trip-out seriously affects a system’s stability and power supply reliability. In this paper, the reasons for high lightning trip-out rates in electric power transmission lines are analyzed in detail from three perspectives, as follows: the substandard lightning resistance level, lightning complexity at a mid-point between towers, and the complexity of first and subsequent lightning stroke conditions. Experiments and simulations demonstrate that the solid-phase gas arc-extinguishing method has a strong ability to extinguish power–frequency continuous-current arcs and to protect against first and subsequent lightning strokes. Since the time taken by gas arc-extinguishing is much less than the response time of relay protection, trip accidents caused by lightning strikes can be avoided and the trip rates of lightning strikes can be reduced using this method. The case analysis and practical operation results show that the solid-phase gas arc-extinguishing lightning protection method can reduce the lightning trip-out rate by more than 90%, completely solve the problem of high lightning trip-out rates, and significantly improve the reliability of power supply.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-02-12
DOI
https://doi.org/10.3390/en18040857
Citations
5
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
5.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Causes and Countermeasures of High Lightning Trip-Out Rate on Electric Transmission Lines

Jieting Bi, Jufeng Wang
5 citations
Energies
Lightning and Electromagnetic Phenomena
5.77
article

Study on the Causes and Countermeasures of High Lightning Trip-Out Rate on Electric Transmission Lines

Jieting Bi, Jufeng Wang
article en
5 citations

Abstract

Trip faults are obviously increased by frequent lightning strikes, and increasing lightning trip-out seriously affects a system’s stability and power supply reliability. In this paper, the reasons for high lightning trip-out rates in electric power transmission lines are analyzed in detail from three perspectives, as follows: the substandard lightning resistance level, lightning complexity at a mid-point between towers, and the complexity of first and subsequent lightning stroke conditions. Experiments and simulations demonstrate that the solid-phase gas arc-extinguishing method has a strong ability to extinguish power–frequency continuous-current arcs and to protect against first and subsequent lightning strokes. Since the time taken by gas arc-extinguishing is much less than the response time of relay protection, trip accidents caused by lightning strikes can be avoided and the trip rates of lightning strikes can be reduced using this method. The case analysis and practical operation results show that the solid-phase gas arc-extinguishing lightning protection method can reduce the lightning trip-out rate by more than 90%, completely solve the problem of high lightning trip-out rates, and significantly improve the reliability of power supply.

EnergiesVol. 18(4)
Guangxi University (CN), Jiangsu Vocational College of Medicine (CN)
Openalex Percentile: Top 5%
Lightning and Electromagnetic Phenomena
5.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.