Pupil wobble in point-scanning retinal optical coherence tomography systems

Optical coherence tomography (OCT) systems utilize 2D scanning methods to acquire reflectance-based volumetric images of samples, such as the human retina, with micrometer-scale depth resolution. A common method for performing this scanning at high speeds is to use a pair of sequential, single-axis galvanometer scanners. An undesired effect of using separated scanners is the variation in the beam position at the pupil plane, a phenomenon known as beam wander or pupil wobble. This can lead to loss of signal and vignetting artifacts in the resulting images. To overcome these limitations, we propose a method to deterministically analyze the pupil wobble in a given retinal OCT system and to correct for the displacement using pupil tracking OCT with a 2D scanning mirror placed anti-conjugate to the pupil plane. We demonstrate that we can model the pattern of pupil wobble present in any OCT system both theoretically and empirically and then use a pupil tracking system to correct for the displacement of the beam to acquire OCT images without the imposed artifacts.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-02-12
DOI
https://doi.org/10.1364/ol.547035
Citations
2
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
3.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pupil wobble in point-scanning retinal optical coherence tomography systems

Joseph A. Izatt, Ryan P. McNabb, Pablo Ortiz, Amit Narawane et al.
2 citations
Optics Letters
Glaucoma and retinal disorders
3.41
article

Pupil wobble in point-scanning retinal optical coherence tomography systems

Joseph A. Izatt, Ryan P. McNabb, Pablo Ortiz, Amit Narawane, Mark Draelos, Anthony N. Kuo
article en
2 citations

Abstract

Optical coherence tomography (OCT) systems utilize 2D scanning methods to acquire reflectance-based volumetric images of samples, such as the human retina, with micrometer-scale depth resolution. A common method for performing this scanning at high speeds is to use a pair of sequential, single-axis galvanometer scanners. An undesired effect of using separated scanners is the variation in the beam position at the pupil plane, a phenomenon known as beam wander or pupil wobble. This can lead to loss of signal and vignetting artifacts in the resulting images. To overcome these limitations, we propose a method to deterministically analyze the pupil wobble in a given retinal OCT system and to correct for the displacement using pupil tracking OCT with a 2D scanning mirror placed anti-conjugate to the pupil plane. We demonstrate that we can model the pattern of pupil wobble present in any OCT system both theoretically and empirically and then use a pupil tracking system to correct for the displacement of the beam to acquire OCT images without the imposed artifacts.

Optics LettersVol. 50(6)
University of Michigan (US), Duke Medical Center (US)
National Eye Institute
Openalex Percentile: Top 10%
Glaucoma and retinal disorders
3.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.