Analysis And Preventive Measures of Abnormal Wire Loss Caused By Wrong Measurement Information

This paper is based on an instance happened in a 10kV on-grid hydropower station, the file information was not corrected in the marketing business system in time after the staff replaced the CT on site, resulting in the inconsistency of CT transformation ratio and measurement magnification between the site and the system, leading to an abnormal on-grid electricity and 10kV wire loss. This paper analyzes the change regularity of the measurement data before and after replacing the CT, combines the error theory, uses the correction coefficient method and the relative error method, calculates the refunded and replenished electricity respectively, analyzes the abnormal wire loss caused by the inconsistent measurement magnification, and puts forward detailed preventive measures to prevent various risks effectively.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/iciba62489.2024.10868515
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis And Preventive Measures of Abnormal Wire Loss Caused By Wrong Measurement Information

Jing Zou, Tian Luo, Shiliang Chang, Kai Duan et al.
Engineering Applied Research
article

Analysis And Preventive Measures of Abnormal Wire Loss Caused By Wrong Measurement Information

Jing Zou, Tian Luo, Shiliang Chang, Kai Duan, Ke Zheng, Tianyu Shi, Chaojun Li
article en

Abstract

This paper is based on an instance happened in a 10kV on-grid hydropower station, the file information was not corrected in the marketing business system in time after the staff replaced the CT on site, resulting in the inconsistency of CT transformation ratio and measurement magnification between the site and the system, leading to an abnormal on-grid electricity and 10kV wire loss. This paper analyzes the change regularity of the measurement data before and after replacing the CT, combines the error theory, uses the correction coefficient method and the relative error method, calculates the refunded and replenished electricity respectively, analyzes the abnormal wire loss caused by the inconsistent measurement magnification, and puts forward detailed preventive measures to prevent various risks effectively.

State Grid Corporation of China (China) (CN)
Gender equality
Openalex Percentile: Top 70%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis And Preventive Measures of Abnormal Wire Loss Caused By Wrong Measurement Information — Jing Zou, Tian Luo, et al. · (2024) | TGRS Research Map | TGRS