B<sub>0</sub> Magnetic Field Conditions in the Human Heart at 3 T Across One Thousand Subjects: A Numerical Simulation Study

Functional scans in cardiovascular magnetic resonance (CMR) adopting bSSFP sequences suffer from dark band artifacts due to B<sub>0</sub> inhomogeneity. The best remedy to mitigate this issue is through cardiac B<sub>0</sub> shimming. The development of an optimal B<sub>0</sub> shim strategy for the human heart is hindered by a limited understanding of B<sub>0</sub> conditions in clinical diagnostic orientations of CMR. Here, we present high-resolution B<sub>0</sub> distributions in cardiac imaging planes, derived from simulations utilizing high-resolution computed tomography (CT) images from 1008 subjects, and present an oblique slicing method to derive such B<sub>0</sub> distributions. This study also presents a theoretical analysis of spherical harmonic B<sub>0</sub> shimming at 3 T using a static global approach and slice-specific dynamic shim updating in the short-axis view of human hearts. The characteristics of cardiac B<sub>0</sub> conditions along with spherical harmonic shimming were correlated with the subjects' demographic parameters, with weak or no correlations, suggesting limited demographic commonality and predominantly subject-specific characteristics in cardiac B<sub>0</sub>. The segmented lung volume shows more significant associations and relatively higher correlations with B<sub>0</sub> conditions, indicating that B<sub>0</sub> conditions in the heart rely on the anatomy surrounding the heart more than overall body shape and size. This research provides a basis for the development of optimized cardiac B<sub>0</sub> shim strategies.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-02-10
DOI
https://doi.org/10.1002/nbm.70006
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B0 Magnetic Field Conditions in the Human Heart at 3 T Across One Thousand Subjects: A Numerical Simulation Study

Sachin Jambawalikar, Christoph Juchem, Andrew Jeffrey Einstein, Sebastian Theilenberg et al.
1 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
1.36
article

B0 Magnetic Field Conditions in the Human Heart at 3 T Across One Thousand Subjects: A Numerical Simulation Study

Sachin Jambawalikar, Christoph Juchem, Andrew Jeffrey Einstein, Sebastian Theilenberg, Boyu Peng, Yun Shang, Wolfgang Schreiber
article en
1 citations

Abstract

Functional scans in cardiovascular magnetic resonance (CMR) adopting bSSFP sequences suffer from dark band artifacts due to B<sub>0</sub> inhomogeneity. The best remedy to mitigate this issue is through cardiac B<sub>0</sub> shimming. The development of an optimal B<sub>0</sub> shim strategy for the human heart is hindered by a limited understanding of B<sub>0</sub> conditions in clinical diagnostic orientations of CMR. Here, we present high-resolution B<sub>0</sub> distributions in cardiac imaging planes, derived from simulations utilizing high-resolution computed tomography (CT) images from 1008 subjects, and present an oblique slicing method to derive such B<sub>0</sub> distributions. This study also presents a theoretical analysis of spherical harmonic B<sub>0</sub> shimming at 3 T using a static global approach and slice-specific dynamic shim updating in the short-axis view of human hearts. The characteristics of cardiac B<sub>0</sub> conditions along with spherical harmonic shimming were correlated with the subjects' demographic parameters, with weak or no correlations, suggesting limited demographic commonality and predominantly subject-specific characteristics in cardiac B<sub>0</sub>. The segmented lung volume shows more significant associations and relatively higher correlations with B<sub>0</sub> conditions, indicating that B<sub>0</sub> conditions in the heart rely on the anatomy surrounding the heart more than overall body shape and size. This research provides a basis for the development of optimized cardiac B<sub>0</sub> shim strategies.

NMR in BiomedicineVol. 38(3)
NewYork–Presbyterian Hospital (US), City University of New York (US), Cornell University (US), Columbia University Irving Medical Center (US), New York Hospital Queens (US), Comprehensive Cancer Center Mainfranken (DE), Universitätsklinikum Würzburg (DE), Medical University of Vienna (AT), Columbia University (US)
Columbia University, National Institutes of Health
Good health and well-being
Openalex Percentile: Top 24%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies