Dimensional Stability and Accuracy of Silicone Impression Materials After Ozone Water Disinfection: An In Vitro Study

<b>Objectives:</b> This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. <b>Materials and Methods:</b> According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05). <b>Results:</b> The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001). <b>Conclusion:</b> Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.

Authors

Institutions

Publication Details

Journal
Frontiers in Dentistry
Published
2025-02-10
DOI
https://doi.org/10.18502/fid.v22i5.17838
Primary Topic
Textile materials and evaluations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dimensional Stability and Accuracy of Silicone Impression Materials After Ozone Water Disinfection: An In Vitro Study

Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam, Abinaya Kutralanathan
Frontiers in Dentistry
Textile materials and evaluations
article

Dimensional Stability and Accuracy of Silicone Impression Materials After Ozone Water Disinfection: An In Vitro Study

Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam, Abinaya Kutralanathan
article en

Abstract

<b>Objectives:</b> This study evaluated the effect of ozone water disinfection on dimensional stability and accuracy of silicone impression materials. <b>Materials and Methods:</b> According to ISO-4823, a stainless-steel die was fabricated for this in vitro study. Three horizontal parallel lines, namely x, y, and z (25, 50, and 75µm in width and 25mm in length) running perpendicular to two vertical lines, namely D1 and D2 (0.075±0.008mm wide), were created on the superior surface of the die. Group A served as the control group with no disinfection. Disinfection was performed with 2% glutaraldehyde in group B, 5.25% sodium hypochlorite in group C, and ozone water in group D for 10 minutes. Totally, 60 samples were fabricated. The silicone impression samples were allowed to polymerize in a thermostatically controlled water bath at 35±1ºC for 10 minutes. The dimensional stability and accuracy of the silicone impression samples were evaluated by using a video measuring microscope and an optical microscope. Data were analyzed by two-way ANOVA followed by post-hoc analysis with the Scheffe test (alpha=0.05). <b>Results:</b> The highest dimensional stability (25.01mm) and accuracy (25.02µm) were seen in addition silicone putty and light body impression with ozone water disinfection, and the lowest parameters were seen in condensation silicon putty and light body disinfected with 2% glutaraldehyde (24.87mm and 24.88 µm, respectively); this difference was statistically significant (P<0.001). <b>Conclusion:</b> Ozone water disinfection caused minimal changes in dimensional stability and accuracy when compared to 2% glutaraldehyde and 5.25% sodium hypochlorite disinfection.

Frontiers in DentistryVol. 22
SRM Dental College (IN)
Openalex Percentile: Top 98%
Textile materials and evaluations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dimensional Stability and Accuracy of Silicone Impression Materials After Ozone Water Disinfection: An In Vitro Study — Ahila Singaravel Chidambaranathan, Muthukumar Balasubramaniam, et al. · Frontiers in Dentistry (2025) | TGRS Research Map | TGRS