Spectacular Application of Isoindole‐Based Fluorophore for Mirabegron Assay in Tablets and Biological Fluids (Urine/Plasma). Assessment of Method Blueness and Whiteness

The FDA has approved mirabegron (MBG) for alleviating urgency in micturition and incontinence. Its mechanism of action involves the activation of β<sub>3</sub>-adrenoreceptors. The present research outlines a novel, highly sensitive, and cost-effective protocol for analyzing MBG. The current research relies on MBG interaction with o-phthalaldehyde alongside 2-mercaptoethanol. The resulting isoindole fluorophore was quantified at λ<sub>ex</sub> 337.7 and λ<sub>em</sub> 433.7 nm. A comprehensive analysis was conducted to systematically examine and enhance the several experimental factors that impact the creation of the isoindole-based fluorophore outcome. A linear correlation was established by precisely manipulating these variables, demonstrating that the increase in fluorescence strength is directly correlated to the quantity of MBG within the range of 30 to 1000 ng/mL. The analytical method was able to reliably detect MBG concentrations as low as 9 ng/mL and accurately quantify levels down to 27.5 ng/mL. This analytical procedure was effectively employed to determine the concentration of MBG in commercially available tablet formulations, as well as in plasma/urine samples. Furthermore, the strategy was extended to assess the content uniformity of MBG-containing products, providing results with satisfactory accuracy and precision. Importantly, this approach is cost-effective, environmentally friendly, and can be readily implemented for quality control and routine monitoring of MBG in pharmaceutical products. The suggested approach was evaluated utilizing the RGB12 and BAGI tools. The outcomes abundantly show the practicability and integrity of the planned strategy.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-02-01
DOI
https://doi.org/10.1002/bio.70120
Citations
4
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
7.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectacular Application of Isoindole‐Based Fluorophore for Mirabegron Assay in Tablets and Biological Fluids (Urine/Plasma). Assessment of Method Blueness and Whiteness

Bandar R. Alsehli, Mohamed A. El Hamd, Wael A. Mahdi, Sultan Alshehri et al.
4 citations
Luminescence
Urinary Bladder and Prostate Research
7.35
article

Spectacular Application of Isoindole‐Based Fluorophore for Mirabegron Assay in Tablets and Biological Fluids (Urine/Plasma). Assessment of Method Blueness and Whiteness

Bandar R. Alsehli, Mohamed A. El Hamd, Wael A. Mahdi, Sultan Alshehri, Safaa F. Saleh, Ahmed A. Abu‐hassan
article en
4 citations

Abstract

The FDA has approved mirabegron (MBG) for alleviating urgency in micturition and incontinence. Its mechanism of action involves the activation of β<sub>3</sub>-adrenoreceptors. The present research outlines a novel, highly sensitive, and cost-effective protocol for analyzing MBG. The current research relies on MBG interaction with o-phthalaldehyde alongside 2-mercaptoethanol. The resulting isoindole fluorophore was quantified at λ<sub>ex</sub> 337.7 and λ<sub>em</sub> 433.7 nm. A comprehensive analysis was conducted to systematically examine and enhance the several experimental factors that impact the creation of the isoindole-based fluorophore outcome. A linear correlation was established by precisely manipulating these variables, demonstrating that the increase in fluorescence strength is directly correlated to the quantity of MBG within the range of 30 to 1000 ng/mL. The analytical method was able to reliably detect MBG concentrations as low as 9 ng/mL and accurately quantify levels down to 27.5 ng/mL. This analytical procedure was effectively employed to determine the concentration of MBG in commercially available tablet formulations, as well as in plasma/urine samples. Furthermore, the strategy was extended to assess the content uniformity of MBG-containing products, providing results with satisfactory accuracy and precision. Importantly, this approach is cost-effective, environmentally friendly, and can be readily implemented for quality control and routine monitoring of MBG in pharmaceutical products. The suggested approach was evaluated utilizing the RGB12 and BAGI tools. The outcomes abundantly show the practicability and integrity of the planned strategy.

LuminescenceVol. 40(2)
Al-Azhar University (EG), South Valley University (EG), Shaqra University (SA), Taibah University (SA), King Saud University (SA), Fayoum University (EG), Assiut University (EG), Jazan University (SA)
King Saud University
Life in Land
Openalex Percentile: Top 4%
Urinary Bladder and Prostate Research
7.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.