Three-Dimensional Coordinate-Based Detection of PCO Using the Rotating Antenna Method

Considering the non-perpendicularity of the antenna rotation axis, a three-dimensional coordinate-based method for detecting the antenna phase center is proposed. This method involves fitting a spatial plane to the three-dimensional coordinate points, projecting them onto the plane, and then rotating the plane to achieve a horizontal orientation. The rotation points are then fitted with a least squares circle to evaluate the deviation of the antenna rotation center and the phase center. Experimental validation demonstrated that when only the horizontal coordinates are considered, the fitted phase center deviation was 1.3 mm. In contrast, using the method described in this article, the fitted phase center deviation was determined to be 3.0 mm.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/iciba62489.2024.10868882
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Dimensional Coordinate-Based Detection of PCO Using the Rotating Antenna Method

Ya Ban, Xinping Xu, Lingjian Zeng, Tianhao Fei et al.
Analytical Chemistry and Sensors
article

Three-Dimensional Coordinate-Based Detection of PCO Using the Rotating Antenna Method

Ya Ban, Xinping Xu, Lingjian Zeng, Tianhao Fei, Xin Kang
article en

Abstract

Considering the non-perpendicularity of the antenna rotation axis, a three-dimensional coordinate-based method for detecting the antenna phase center is proposed. This method involves fitting a spatial plane to the three-dimensional coordinate points, projecting them onto the plane, and then rotating the plane to achieve a horizontal orientation. The rotation points are then fitted with a least squares circle to evaluate the deviation of the antenna rotation center and the phase center. Experimental validation demonstrated that when only the horizontal coordinates are considered, the fitted phase center deviation was 1.3 mm. In contrast, using the method described in this article, the fitted phase center deviation was determined to be 3.0 mm.

Chongqing Metrology Quality Inspection and Research Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 72%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Three-Dimensional Coordinate-Based Detection of PCO Using the Rotating Antenna Method — Ya Ban, Xinping Xu, et al. · (2024) | TGRS Research Map | TGRS