Automated in-toilet hydration sensor for urinalysis on participants during a four-day prolonged walking exercise event: Prototype validation study

Underhydration is a common problem in elderly, which can lead to serious health complications if left untreated. However, currently, there is no sufficient, non-obtrusive method to monitor underhydration status automatically. Therefore, a prototype was developed that automatically measures urine concentration during a toilet visit. This study validates this prototype for its capability to repeatedly and accurately measure the urine of 106 participants participating in a 4-day prolonged walking exercise event. The prototype contains 4 sensors that measure the color, conductivity, pH, and temperature of the urine sample while the participant uses the toilet. In total, the prototype analyzed 514 urine samples. In addition, the urine was automatically collected to measure the gold standard for urine concentration, urine specific gravity (USG), and osmolality. With a linear regression classification model and the USG reference, the data collected with the prototype was classified. The measured reference USG values range between 1.0025 and 1.0345. The prototype measurements strongly correlated to the USG reference, with an R-squared of 0.85 and a mean absolute error of 0.00215. As such, this study reports on a method that allows automated, repeated, and accurate urinalysis during a toilet visit. When used daily, this prototype offers potential for the non-obtrusive and time-effective underhydration estimation by monitoring urine.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2025-02-01
DOI
https://doi.org/10.1016/j.sbsr.2025.100763
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated in-toilet hydration sensor for urinalysis on participants during a four-day prolonged walking exercise event: Prototype validation study

Vera Verbiest, Coen C. W. G. Bongers, E.C. Wentink, Maria T. E. Hopman et al.
Sensing and Bio-Sensing Research
Thermoregulation and physiological responses
article

Automated in-toilet hydration sensor for urinalysis on participants during a four-day prolonged walking exercise event: Prototype validation study

Vera Verbiest, Coen C. W. G. Bongers, E.C. Wentink, Maria T. E. Hopman, Esther Kho, D. T. Young
article en

Abstract

Underhydration is a common problem in elderly, which can lead to serious health complications if left untreated. However, currently, there is no sufficient, non-obtrusive method to monitor underhydration status automatically. Therefore, a prototype was developed that automatically measures urine concentration during a toilet visit. This study validates this prototype for its capability to repeatedly and accurately measure the urine of 106 participants participating in a 4-day prolonged walking exercise event. The prototype contains 4 sensors that measure the color, conductivity, pH, and temperature of the urine sample while the participant uses the toilet. In total, the prototype analyzed 514 urine samples. In addition, the urine was automatically collected to measure the gold standard for urine concentration, urine specific gravity (USG), and osmolality. With a linear regression classification model and the USG reference, the data collected with the prototype was classified. The measured reference USG values range between 1.0025 and 1.0345. The prototype measurements strongly correlated to the USG reference, with an R-squared of 0.85 and a mean absolute error of 0.00215. As such, this study reports on a method that allows automated, repeated, and accurate urinalysis during a toilet visit. When used daily, this prototype offers potential for the non-obtrusive and time-effective underhydration estimation by monitoring urine.

Sensing and Bio-Sensing ResearchVol. 47
HAN University of Applied Sciences (NL), Radboud University Nijmegen (NL), Imec the Netherlands (NL), Radboud University Medical Center (NL)
Openalex Percentile: Top 97%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.