Relay-Fuse Coordination for Enhanced Protection from Low Impedance fault in Radial Distribution Network

Ensuring reliable and secure operation of power distribution networks requires effective over-current protection, which involves correct coordination between the protective devices such as fuses, circuit breaker and relays. This paper examines the coordination between relay tripping and total clearing time of fuse operation, evaluating protective devices performance as primary and backup protection mechanisms at various fault location. The simulation model is designed using PSCAD/EMTDC software, with the IEEE-13 node test feeder system serving as the basis for analysis. The study focuses on the tripping times of relays and fuses operation during low impedance shunt faults, including single-line-to-ground (LG), double-line-to-ground (LLG), and three-line-to-ground (LLLG) faults. This analysis contributes to improving the design and implementation of protection strategies in modern distribution networks.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/akgec62572.2024.10869275
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relay-Fuse Coordination for Enhanced Protection from Low Impedance fault in Radial Distribution Network

Pratibha Sharma, Pushkar Tripathi, Kuwar Yatendra, Arvind Kumar
Power Systems Fault Detection
article

Relay-Fuse Coordination for Enhanced Protection from Low Impedance fault in Radial Distribution Network

Pratibha Sharma, Pushkar Tripathi, Kuwar Yatendra, Arvind Kumar
article en

Abstract

Ensuring reliable and secure operation of power distribution networks requires effective over-current protection, which involves correct coordination between the protective devices such as fuses, circuit breaker and relays. This paper examines the coordination between relay tripping and total clearing time of fuse operation, evaluating protective devices performance as primary and backup protection mechanisms at various fault location. The simulation model is designed using PSCAD/EMTDC software, with the IEEE-13 node test feeder system serving as the basis for analysis. The study focuses on the tripping times of relays and fuses operation during low impedance shunt faults, including single-line-to-ground (LG), double-line-to-ground (LLG), and three-line-to-ground (LLLG) faults. This analysis contributes to improving the design and implementation of protection strategies in modern distribution networks.

Institute of Engineering (NP), Indian Institute of Management Lucknow (IN)
Climate action
Openalex Percentile: Top 67%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.