Investigation of Operating Point Setting and Stability Behavior of LVDC Arc Flashes

Short circuits in electrical power systems often lead to arc flashes, prompting increased demands for protection, especially in LVDC systems. Static equivalent circuit models are commonly used to estimate arc flash characteristics under steady-state conditions. However, these models typically overlook dynamic behavior around the operating point and its impact on arc fault stability. Laboratory measurements in a DC test circuit with various parameters were conducted to investigate operating point setting and arc fault extinguishing tendencies. Insights into dynamic stability and stability indicators were derived, aiding in the selection of appropriate personal protective equipment (PPE) during hazard assessments.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863658
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Operating Point Setting and Stability Behavior of LVDC Arc Flashes

Sebastian Glaser, Dirk Westermann
Electrical Fault Detection and Protection
article

Investigation of Operating Point Setting and Stability Behavior of LVDC Arc Flashes

Sebastian Glaser, Dirk Westermann
article en

Abstract

Short circuits in electrical power systems often lead to arc flashes, prompting increased demands for protection, especially in LVDC systems. Static equivalent circuit models are commonly used to estimate arc flash characteristics under steady-state conditions. However, these models typically overlook dynamic behavior around the operating point and its impact on arc fault stability. Laboratory measurements in a DC test circuit with various parameters were conducted to investigate operating point setting and arc fault extinguishing tendencies. Insights into dynamic stability and stability indicators were derived, aiding in the selection of appropriate personal protective equipment (PPE) during hazard assessments.

Technische Universität Ilmenau (DE)
Openalex Percentile: Top 75%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.