Contribution of storage to adequacy in power systems with a large share of renewable energy resources

The variability of renewable energy sources (RES), threatening the adequacy of power systems, could be dampened using storage. Concretely, RES would be stored during periods of excess and used when needed. However, the impact of the operating strategy on the loss of load expectation (LOLE) remains an open question. Therefore, this paper studies the impact of different storage operating strategies on adequacy indicators. To do so, five strategies are defined: yearly costs minimization with single and depth-dependent value of lost load (VoLL), LOLE minimization, and weekly costs minimization, with and without water values. Using Monte Carlo methods, these are applied to three case studies. The various operating strategies give spread results in terms of LOLE, with up to a factor 10 between the lowest and highest value. Weekly minimization gives poorer adequacy indicators. This paper recommends weekly costs optimization, with a depth-dependent VoLL and with water values, in adequacy studies.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863731
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contribution of storage to adequacy in power systems with a large share of renewable energy resources

Pierre‐Etienne Labeau, Pierre Henneaux, Butrint Avdijaj
Smart Grid Energy Management
article

Contribution of storage to adequacy in power systems with a large share of renewable energy resources

Pierre‐Etienne Labeau, Pierre Henneaux, Butrint Avdijaj
article en

Abstract

The variability of renewable energy sources (RES), threatening the adequacy of power systems, could be dampened using storage. Concretely, RES would be stored during periods of excess and used when needed. However, the impact of the operating strategy on the loss of load expectation (LOLE) remains an open question. Therefore, this paper studies the impact of different storage operating strategies on adequacy indicators. To do so, five strategies are defined: yearly costs minimization with single and depth-dependent value of lost load (VoLL), LOLE minimization, and weekly costs minimization, with and without water values. Using Monte Carlo methods, these are applied to three case studies. The various operating strategies give spread results in terms of LOLE, with up to a factor 10 between the lowest and highest value. Weekly minimization gives poorer adequacy indicators. This paper recommends weekly costs optimization, with a depth-dependent VoLL and with water values, in adequacy studies.

Université Libre de Bruxelles (BE)
Affordable and clean energy
Openalex Percentile: Top 75%
Smart Grid Energy Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.