Phase imbalance impact on operating envelope for low-voltage distribution grid

Distribution System Operators must ensure safe operation of the Low Voltage distribution grid in the face of upcoming challenges posed by new assets (e.g. photovoltaic panels, electric vehicles) and new activities (e.g. energy sharing, frequency reserves). This task is further complicated by the fact that end-users may be unevenly connected to the phases without Distribution System Operators being aware of it. This can lead to unexpected voltage or current congestions. This paper presents an innovative method, a relaxed unbalanced three-phase optimal power flow, to compute the maximum day-ahead flexibility per end-user that can be unlocked while ensuring safe use of the low voltage grid, i.e. the operating envelope. Additionally, the paper shows results that controlling reactive power on the LV network could not increase flexibility potential and counteract imbalances caused by unevenly distributed phase connections.

Authors

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863469
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase imbalance impact on operating envelope for low-voltage distribution grid

Patrick Hendrick, Hamada Almasalma, Pierre Henneaux, Lionel Delchambre
Power Systems and Technologies
article

Phase imbalance impact on operating envelope for low-voltage distribution grid

Patrick Hendrick, Hamada Almasalma, Pierre Henneaux, Lionel Delchambre
article en

Abstract

Distribution System Operators must ensure safe operation of the Low Voltage distribution grid in the face of upcoming challenges posed by new assets (e.g. photovoltaic panels, electric vehicles) and new activities (e.g. energy sharing, frequency reserves). This task is further complicated by the fact that end-users may be unevenly connected to the phases without Distribution System Operators being aware of it. This can lead to unexpected voltage or current congestions. This paper presents an innovative method, a relaxed unbalanced three-phase optimal power flow, to compute the maximum day-ahead flexibility per end-user that can be unlocked while ensuring safe use of the low voltage grid, i.e. the operating envelope. Additionally, the paper shows results that controlling reactive power on the LV network could not increase flexibility potential and counteract imbalances caused by unevenly distributed phase connections.

Affordable and clean energy
Openalex Percentile: Top 75%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.