Analysis of Short Circuit Characteristics Between Windings of Dry-Type Air-Core Shunt Reactor

Dry-type air-core shunt reactor is an important equipment for reactive power compensation in power grid. In view of the lack of effective monitoring means for its winding short-circuit fault, this paper establishes a simulation model of dry-type air-core shunt reactor through finite element analysis software to analyze the influence of winding short-circuit fault on the reactor. On the basis of verifying the reliability of the model, the short circuit between the same turn and the short circuit between different turns are set at different positions in different layers of the reactor winding, and the influence of the short circuit between the turns on the electrical parameters of the dry-type air-core shunt reactor is obtained. The results show that the influence of short circuit between different turns on the change rate of electrical parameters of dry-type air-core shunt reactor is greater than that of short circuit between the same turns. The short circuit between different turns can be judged by the change of equivalent resistance, power factor and active power loss.

Authors

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/acepe63527.2024.10871608
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Short Circuit Characteristics Between Windings of Dry-Type Air-Core Shunt Reactor

Haijie Zhang, Bo Jiao, Weidong Zhang
Graphite, nuclear technology, radiation studies
article

Analysis of Short Circuit Characteristics Between Windings of Dry-Type Air-Core Shunt Reactor

Haijie Zhang, Bo Jiao, Weidong Zhang
article en

Abstract

Dry-type air-core shunt reactor is an important equipment for reactive power compensation in power grid. In view of the lack of effective monitoring means for its winding short-circuit fault, this paper establishes a simulation model of dry-type air-core shunt reactor through finite element analysis software to analyze the influence of winding short-circuit fault on the reactor. On the basis of verifying the reliability of the model, the short circuit between the same turn and the short circuit between different turns are set at different positions in different layers of the reactor winding, and the influence of the short circuit between the turns on the electrical parameters of the dry-type air-core shunt reactor is obtained. The results show that the influence of short circuit between different turns on the change rate of electrical parameters of dry-type air-core shunt reactor is greater than that of short circuit between the same turns. The short circuit between different turns can be judged by the change of equivalent resistance, power factor and active power loss.

Affordable and clean energy
Openalex Percentile: Top 83%
Graphite, nuclear technology, radiation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.