The weather impact on corona losses of 330 kV aging transmission lines

The main objective of this work is to investigate the characteristics of different weather parameters on corona losses for aging overhead transmission lines using synchronized phasor measurements. The study is conducted for a long-term assessment using two years of data based on PMU measurements collected from Estonian TSO and weather data from the Estonian Environmental Agency. This research gives insight into information about weather factors influencing corona loss for two different aged transmission lines using a statistical graphical study. It is generally believed that aged transmission lines are more sensitive as they are exposed to different environmental conditions, leading to the deterioration of the line performances. Therefore, it would seem appropriate to investigate the factors influencing corona loss in an overhead transmission line. These results can be the basis for transmission system operators to reduce the power loss purchase and improve corona loss management under complex weather conditions to increase power grid efficiency.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863024
Citations
2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The weather impact on corona losses of 330 kV aging transmission lines

Jako Kilter, Kaur Tuttelberg, Pradeep Kumar Gupta
2 citations
High voltage insulation and dielectric phenomena
0.23
article

The weather impact on corona losses of 330 kV aging transmission lines

Jako Kilter, Kaur Tuttelberg, Pradeep Kumar Gupta
article en
2 citations

Abstract

The main objective of this work is to investigate the characteristics of different weather parameters on corona losses for aging overhead transmission lines using synchronized phasor measurements. The study is conducted for a long-term assessment using two years of data based on PMU measurements collected from Estonian TSO and weather data from the Estonian Environmental Agency. This research gives insight into information about weather factors influencing corona loss for two different aged transmission lines using a statistical graphical study. It is generally believed that aged transmission lines are more sensitive as they are exposed to different environmental conditions, leading to the deterioration of the line performances. Therefore, it would seem appropriate to investigate the factors influencing corona loss in an overhead transmission line. These results can be the basis for transmission system operators to reduce the power loss purchase and improve corona loss management under complex weather conditions to increase power grid efficiency.

Tallinn University of Technology (EE)
Openalex Percentile: Top 49%
High voltage insulation and dielectric phenomena
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The weather impact on corona losses of 330 kV aging transmission lines — Jako Kilter, Kaur Tuttelberg, et al. · (2024) | TGRS Research Map | TGRS