Extending AC Security Constrained Optimal Power Flow for Low Inertia Systems with Artificial Neural Network-based Frequency Stability Constraints

Frequency stability in inverter-based renewable energy sources (RES)-dominated, low-inertia, power systems is a timely challenge. This paper employs a systematic approach, utilizing an artificial neural network (ANN) and dynamic simulation, to infer two key frequency stability indicators: nadir and rate of change of frequency (RoCoF). By reformulating the ANN mathematical model, these indicators are then integrated as mixed-integer non-linear constraints into a classical AC security-constrained optimal power flow (AC SCOPF), resulting in the proposed AC-F-SCOPF problem. The results of the proposed AC-F-SCOPF on the IEEE 39-bus system show that the problem identifies accurately the synchronous condensers which must run to ensure the frequency stability.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863287
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extending AC Security Constrained Optimal Power Flow for Low Inertia Systems with Artificial Neural Network-based Frequency Stability Constraints

Carlos Moreira, Florin Capitanescu, Pedro Barbeiro, Filipe Soares et al.
Power System Optimization and Stability
article

Extending AC Security Constrained Optimal Power Flow for Low Inertia Systems with Artificial Neural Network-based Frequency Stability Constraints

Carlos Moreira, Florin Capitanescu, Pedro Barbeiro, Filipe Soares, J. Gouveia, Mohammad Iman Alizadeh
article en

Abstract

Frequency stability in inverter-based renewable energy sources (RES)-dominated, low-inertia, power systems is a timely challenge. This paper employs a systematic approach, utilizing an artificial neural network (ANN) and dynamic simulation, to infer two key frequency stability indicators: nadir and rate of change of frequency (RoCoF). By reformulating the ANN mathematical model, these indicators are then integrated as mixed-integer non-linear constraints into a classical AC security-constrained optimal power flow (AC SCOPF), resulting in the proposed AC-F-SCOPF problem. The results of the proposed AC-F-SCOPF on the IEEE 39-bus system show that the problem identifies accurately the synchronous condensers which must run to ensure the frequency stability.

Luxembourg Institute of Science and Technology (LU), INESC TEC (PT)
Affordable and clean energy
Openalex Percentile: Top 75%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.