Noisy PMU Data Recovery in Transient Conditions through Self-Attention Neural Networks

This paper utilizes the self-attention-based Imputation method to effectively manage missing data in Phasor Measurement Units (PMUs) during transient power system disturbances. This self-attention-based method processes multivariate, noisy datasets, improving data accuracy during disturbances under different missing data patterns and ratios. We conducted a comprehensive comparative analysis with other imputation methods using the IEEE 39-bus New England system. As inputs for the imputation, we employed voltage magnitudes and angles. Results demonstrate the superiority of this method in maintaining data integrity and significantly improving the accuracy of imputation under noisy and transient conditions. In comparative testing, this method reduced Mean Absolute Error (MAE) by approximately 5% to 50% across different cases compared to the best result from other methods in most scenarios, although it underperformed slightly in highly sparse data conditions with a missing ratio of 0.9. The method demonstrated robustness through its high imputation accuracy and fast performance, confirming that it is well-suited for real-time applications in smart grid monitoring, thanks to its ability to process data in parallel.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863227
Primary Topic
Neural Networks and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noisy PMU Data Recovery in Transient Conditions through Self-Attention Neural Networks

Mousa Afrasiabi, Ramin Bahmani
Neural Networks and Applications
article

Noisy PMU Data Recovery in Transient Conditions through Self-Attention Neural Networks

Mousa Afrasiabi, Ramin Bahmani
article en

Abstract

This paper utilizes the self-attention-based Imputation method to effectively manage missing data in Phasor Measurement Units (PMUs) during transient power system disturbances. This self-attention-based method processes multivariate, noisy datasets, improving data accuracy during disturbances under different missing data patterns and ratios. We conducted a comprehensive comparative analysis with other imputation methods using the IEEE 39-bus New England system. As inputs for the imputation, we employed voltage magnitudes and angles. Results demonstrate the superiority of this method in maintaining data integrity and significantly improving the accuracy of imputation under noisy and transient conditions. In comparative testing, this method reduced Mean Absolute Error (MAE) by approximately 5% to 50% across different cases compared to the best result from other methods in most scenarios, although it underperformed slightly in highly sparse data conditions with a missing ratio of 0.9. The method demonstrated robustness through its high imputation accuracy and fast performance, confirming that it is well-suited for real-time applications in smart grid monitoring, thanks to its ability to process data in parallel.

University of Luxembourg (LU)
Openalex Percentile: Top 75%
Neural Networks and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.