Voltage Accelerated Directional Overcurrent Relays for Microgrid Protection

This paper proposes a voltage-accelerated directional overcurrent relay (VADOCR) based protection scheme for microgrids. The reduction in the fault current because of the domination of inverted-based renewable (IBR) power generation in microgrids has been taken care of by accelerating the operating time of relays through the fault voltage. This is achieved using a novel time-current-voltage characteristic of standard inverse definite minimum time relay. To compute the setting of the developed VADOCRs, the protection coordination problem has been formulated as an optimization problem and solved using a novel hybrid differential particle swarm optimization (DPSO) algorithm. To validate the proposed VADORCs and DPSO, the protection scheme for a standard 4-bus microgrid test system has been developed. The suitability and effectiveness of the obtained settings have been analysed. The proposed VADOCRs’ overall performance is impressive and effective in protecting microgrids in the grid-connected and islanded modes of operation.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/icefeet64463.2024.10866777
Citations
1
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage Accelerated Directional Overcurrent Relays for Microgrid Protection

Mahamad Nabab Alam
1 citations
Islanding Detection in Power Systems
0.21
article

Voltage Accelerated Directional Overcurrent Relays for Microgrid Protection

Mahamad Nabab Alam
article en
1 citations

Abstract

This paper proposes a voltage-accelerated directional overcurrent relay (VADOCR) based protection scheme for microgrids. The reduction in the fault current because of the domination of inverted-based renewable (IBR) power generation in microgrids has been taken care of by accelerating the operating time of relays through the fault voltage. This is achieved using a novel time-current-voltage characteristic of standard inverse definite minimum time relay. To compute the setting of the developed VADOCRs, the protection coordination problem has been formulated as an optimization problem and solved using a novel hybrid differential particle swarm optimization (DPSO) algorithm. To validate the proposed VADORCs and DPSO, the protection scheme for a standard 4-bus microgrid test system has been developed. The suitability and effectiveness of the obtained settings have been analysed. The proposed VADOCRs’ overall performance is impressive and effective in protecting microgrids in the grid-connected and islanded modes of operation.

National Institute of Technology Warangal (IN)
Affordable and clean energy
Openalex Percentile: Top 44%
Islanding Detection in Power Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Voltage Accelerated Directional Overcurrent Relays for Microgrid Protection — Mahamad Nabab Alam · (2024) | TGRS Research Map | TGRS