Measurement-based Harmonic Current Modeling of Agricultural Heat Pumps with Active Filters

Harmonic disturbances occur in power distribution systems because of the intensive connection of agricultural heat pumps (AHPs). An effective countermeasure is to equip AHPs with active filters (AFs). However, no harmonic model exists for analytically examining the harmonic suppression effect of AFs. In this study, we measured the harmonic characteristics of an AHP (and an air conditioner) equipped with AFs; the results were used to develop corresponding harmonic current models. AFs are not activated until the active input power of the AHP (and air conditioner) increases to some extent. Thus, a model was developed for the case with an AF and that without an AF; these models are switched according to the effective input power of the AHP. These models can be used for harmonic calculation to prevent harmonic disturbances in distribution systems.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863555
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement-based Harmonic Current Modeling of Agricultural Heat Pumps with Active Filters

Kentaro Fukushima, Kyohei Kawamura, Naotaka Okada
Induction Heating and Inverter Technology
article

Measurement-based Harmonic Current Modeling of Agricultural Heat Pumps with Active Filters

Kentaro Fukushima, Kyohei Kawamura, Naotaka Okada
article en

Abstract

Harmonic disturbances occur in power distribution systems because of the intensive connection of agricultural heat pumps (AHPs). An effective countermeasure is to equip AHPs with active filters (AFs). However, no harmonic model exists for analytically examining the harmonic suppression effect of AFs. In this study, we measured the harmonic characteristics of an AHP (and an air conditioner) equipped with AFs; the results were used to develop corresponding harmonic current models. AFs are not activated until the active input power of the AHP (and air conditioner) increases to some extent. Thus, a model was developed for the case with an AF and that without an AF; these models are switched according to the effective input power of the AHP. These models can be used for harmonic calculation to prevent harmonic disturbances in distribution systems.

Central Research Institute of Electric Power Industry (JP)
Zero hunger
Openalex Percentile: Top 73%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.