Methodology for Optimizing Inter-Row Spacing Of Solar Power Plant

Performance of solar power plant can be improved by implementing optimization techniques which are economical, simple and effective. In this research a methodology has been developed to optimize inter-row spacing of solar power plant with light shadow fall on module. Plant has been designed on PV-SYST software and mathematical calculations has been compared with experimental results at Gurugram, India. Maximum shadow length for different inter-row spacing has been estimated. Effect of shadow length on PV module (320W polycrystalline technology) has been performed on experimental setup. An expected value of annual energy generation for spacing 1, 1.2, 1.3, 1.4, 1.5,1.6 times of the height of module for 1MW plant has been obtained. Energy output has been compared with PV-SYST software, and entities have been cross verified. Hence, economic analysis and payback period estimation has been done for different inter-row spacing, to opt out the optimized inter-row spacing of plant.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/icefeet64463.2024.10866082
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methodology for Optimizing Inter-Row Spacing Of Solar Power Plant

Praveen Kumar Mishra, Ambarisha Mishra, Ashwani Kumar
Power Systems and Renewable Energy
article

Methodology for Optimizing Inter-Row Spacing Of Solar Power Plant

Praveen Kumar Mishra, Ambarisha Mishra, Ashwani Kumar
article en

Abstract

Performance of solar power plant can be improved by implementing optimization techniques which are economical, simple and effective. In this research a methodology has been developed to optimize inter-row spacing of solar power plant with light shadow fall on module. Plant has been designed on PV-SYST software and mathematical calculations has been compared with experimental results at Gurugram, India. Maximum shadow length for different inter-row spacing has been estimated. Effect of shadow length on PV module (320W polycrystalline technology) has been performed on experimental setup. An expected value of annual energy generation for spacing 1, 1.2, 1.3, 1.4, 1.5,1.6 times of the height of module for 1MW plant has been obtained. Energy output has been compared with PV-SYST software, and entities have been cross verified. Hence, economic analysis and payback period estimation has been done for different inter-row spacing, to opt out the optimized inter-row spacing of plant.

National Institute of Technology Patna (IN)
Affordable and clean energy
Openalex Percentile: Top 70%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Methodology for Optimizing Inter-Row Spacing Of Solar Power Plant — Praveen Kumar Mishra, Ambarisha Mishra, et al. · (2024) | TGRS Research Map | TGRS