Testing of insulation systems in accelerated aging conditions

The paper describes the testing procedure of the insulation system of electrical rotating machines with form-wound windings in accordance with the standards IEC 60034-18-31 and IEC 60034-18-42. Testing is based on a comparison of reference insulation system which has given satisfactory service experience and candidate insulation system which is intended to be used instead of existing insulation system. To prove or disprove the reliability of candidate systems in reasonable time, the accelerated aging test is carried out, considering various factors that reduce the life of the insulation system in greater or lesser extent: heat, exposure to mechanical vibrations and moisture (according to IEC 60034-18-31) and voltage (according to IEC 60034-18-42). In order to save materials and easier handling of test samples, tests are carried out on reduced models of coils (so-called formette coils) that are placed in frames imitating the stator core. The purpose of the test is to verify the potential contributions of a new impregnating resin, as well as the addition of nanoparticles in a new impregnating resin in a condition of increased voltage stress due to machine connection to the grid via frequency converter. In addition to the test procedure, the paper presents the results obtained so far.

Authors

Publication Details

Journal
Journal of Energy - Energija
Published
2024-12-15
DOI
https://doi.org/10.37798/2024733517
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing of insulation systems in accelerated aging conditions

Stjepan Car, Slaven Nađ, Josip Treger
4 links
Journal of Energy - Energija
High voltage insulation and dielectric phenomena
article

Testing of insulation systems in accelerated aging conditions

Stjepan Car, Slaven Nađ, Josip Treger
article en

Abstract

The paper describes the testing procedure of the insulation system of electrical rotating machines with form-wound windings in accordance with the standards IEC 60034-18-31 and IEC 60034-18-42. Testing is based on a comparison of reference insulation system which has given satisfactory service experience and candidate insulation system which is intended to be used instead of existing insulation system. To prove or disprove the reliability of candidate systems in reasonable time, the accelerated aging test is carried out, considering various factors that reduce the life of the insulation system in greater or lesser extent: heat, exposure to mechanical vibrations and moisture (according to IEC 60034-18-31) and voltage (according to IEC 60034-18-42). In order to save materials and easier handling of test samples, tests are carried out on reduced models of coils (so-called formette coils) that are placed in frames imitating the stator core. The purpose of the test is to verify the potential contributions of a new impregnating resin, as well as the addition of nanoparticles in a new impregnating resin in a condition of increased voltage stress due to machine connection to the grid via frequency converter. In addition to the test procedure, the paper presents the results obtained so far.

Journal of Energy - EnergijaVol. 73(3)
Openalex Percentile: Top 83%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.