Robust Method Based on XGBoost for Inter-Turn Faults Detection in Air-Core Dry-Type Shunt Reactor

This paper presents the development and evaluation of a new scheme based on a machine learning classifier named eXtreme Gradient Boosting (XGBoost) for detecting inter-turn faults in air-core dry-type shunt reactors. The proposed scheme was developed to protect a 230 kV air-core reactor installed on the Penedo’s bar of the "Nossa Senhora do Socorro - Penedo" transmission line in Brazil. To achieve this, the XGBoost model was trained and tested for a set of different internal faults in the reactor, generated in Matlab, using the time domain solution. Furthermore, different levels of noise were added to the dataset, making the method more robust. The results show that the proposed solution based on XGBoost is effective in detecting interturn faults in the reactor, even for the most challenging cases in which the overcurrent protections fail to operate due to their low sensitivity.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863334
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Method Based on XGBoost for Inter-Turn Faults Detection in Air-Core Dry-Type Shunt Reactor

Demba Diallo, Silvio Giuseppe Di Santo, Giovanni Manassero, Trung Dung Le et al.
Fault Detection and Control Systems
article

Robust Method Based on XGBoost for Inter-Turn Faults Detection in Air-Core Dry-Type Shunt Reactor

Demba Diallo, Silvio Giuseppe Di Santo, Giovanni Manassero, Trung Dung Le, Fernanda Soares Vitor Petite
article en

Abstract

This paper presents the development and evaluation of a new scheme based on a machine learning classifier named eXtreme Gradient Boosting (XGBoost) for detecting inter-turn faults in air-core dry-type shunt reactors. The proposed scheme was developed to protect a 230 kV air-core reactor installed on the Penedo’s bar of the "Nossa Senhora do Socorro - Penedo" transmission line in Brazil. To achieve this, the XGBoost model was trained and tested for a set of different internal faults in the reactor, generated in Matlab, using the time domain solution. Furthermore, different levels of noise were added to the dataset, making the method more robust. The results show that the proposed solution based on XGBoost is effective in detecting interturn faults in the reactor, even for the most challenging cases in which the overcurrent protections fail to operate due to their low sensitivity.

Centre National de la Recherche Scientifique (FR), Universidade de São Paulo (BR), Laboratoire de Génie Électrique et Électronique de Paris (FR), Sorbonne Université (FR), CentraleSupélec (FR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 67%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robust Method Based on XGBoost for Inter-Turn Faults Detection in Air-Core Dry-Type Shunt Reactor — Demba Diallo, Silvio Giuseppe Di Santo, et al. · (2024) | TGRS Research Map | TGRS