Economics and Optimization Analysis of On-grid Hybrid Energy Systems with Controlled Battery Storage towards Net-zero Households - A Case of Different Solar Radiation Profile Zones

The global clean energy transition goals require commitment from every country. Different locations however present different technical and economic viability for increasing the penetration of variable renewable energy (VRE) resources to meet national targets. This work presents a comparative economic and system sizing analysis of PV/wind/battery hybrid energy systems in two different residential locations and climate zones (Ansen, Netherlands (NL)) and Mpoase, Ghana (GH)) to measure and compare the fraction of self-consumption. The system aimed to achieve net-zero energy transfer using a battery with self-consumption (SC) control. The System Analysis Model (SAM) integrated with a multi-parametric economic model was used for system simulations and sizing. The study found that for the same optimum hybrid system size in two different locations, higher SC and cheaper system costs were achieved when the consumption and generation profiles of the VRE were more closely matched in time. Increasing the battery size increases SC and the system cost non-linearly. However, increasing the PV capacity resulted in a non-linear decrease in the SC, the unit installed cost, and the LCOE. For the same PV size of 5 kW, GH and NL had the highest SC of 0.71 and 0.64 respectively. However, with this fraction, the LCOE of NL exceeded its reference LCOE by 100% as the battery size and the installed cost were 2.5 and 1.5 times more than that of GH respectively. In GH, the highest achievable fraction of SC for return on investment was 0.59 and consisted of a 5 kW PV and 10 kWh battery capacity. This gave a simple payback of 18.6 years at an LCOE of 0.18 €/kWh. NL required an additional 1 kW wind turbine to meet the demand and to make the system financially viable at an LCOE of 0.17 €/kWh and installed cost of 6.6 €/W.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/isgteurope62998.2024.10863689
Primary Topic
Electric Vehicles and Infrastructure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Economics and Optimization Analysis of On-grid Hybrid Energy Systems with Controlled Battery Storage towards Net-zero Households - A Case of Different Solar Radiation Profile Zones

M. Laan, Samuel Cudjoe
Electric Vehicles and Infrastructure
article

Economics and Optimization Analysis of On-grid Hybrid Energy Systems with Controlled Battery Storage towards Net-zero Households - A Case of Different Solar Radiation Profile Zones

M. Laan, Samuel Cudjoe
article en

Abstract

The global clean energy transition goals require commitment from every country. Different locations however present different technical and economic viability for increasing the penetration of variable renewable energy (VRE) resources to meet national targets. This work presents a comparative economic and system sizing analysis of PV/wind/battery hybrid energy systems in two different residential locations and climate zones (Ansen, Netherlands (NL)) and Mpoase, Ghana (GH)) to measure and compare the fraction of self-consumption. The system aimed to achieve net-zero energy transfer using a battery with self-consumption (SC) control. The System Analysis Model (SAM) integrated with a multi-parametric economic model was used for system simulations and sizing. The study found that for the same optimum hybrid system size in two different locations, higher SC and cheaper system costs were achieved when the consumption and generation profiles of the VRE were more closely matched in time. Increasing the battery size increases SC and the system cost non-linearly. However, increasing the PV capacity resulted in a non-linear decrease in the SC, the unit installed cost, and the LCOE. For the same PV size of 5 kW, GH and NL had the highest SC of 0.71 and 0.64 respectively. However, with this fraction, the LCOE of NL exceeded its reference LCOE by 100% as the battery size and the installed cost were 2.5 and 1.5 times more than that of GH respectively. In GH, the highest achievable fraction of SC for return on investment was 0.59 and consisted of a 5 kW PV and 10 kWh battery capacity. This gave a simple payback of 18.6 years at an LCOE of 0.18 €/kWh. NL required an additional 1 kW wind turbine to meet the demand and to make the system financially viable at an LCOE of 0.17 €/kWh and installed cost of 6.6 €/W.

Hanze University of Applied Sciences (NL)
Affordable and clean energy
Openalex Percentile: Top 75%
Electric Vehicles and Infrastructure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Economics and Optimization Analysis of On-grid Hybrid Energy Systems with Controlled Battery Storage towards Net-zero Households - A Case of Different Solar Radiation Profile Zones — M. Laan, Samuel Cudjoe · (2024) | TGRS Research Map | TGRS