Evaluation of electrically boosted natural gas fired glass furnace performance by using data reconciliation method

The purpose of this study is to address the challenges posed by errors in sensor measurements and unmeasured variables in glass-melting furnaces, which can lead to misleading information regarding furnace performance. We implemented the Data Reconciliation Methodology to filter errors and estimate unmeasured variables, aiming to achieve accurate and reliable furnace characteristics. This task involved generating a dataset from measured furnace variables, and conducting observability and redundancy checks. By applying the data reconciliation method, gross errors were detected and removed, and the database was filtered for noise. Additionally, we estimated the necessary unmeasured variables. The results demonstrated the effectiveness of our approach. With accurate data, the energy efficiency, regenerator efficiency, and specific energy consumption of the furnace were found to be 38.63 %, 62.72 %, and 4159.84 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mfrac><mml:mrow><mml:mi>k</mml:mi> <mml:mi>J</mml:mi></mml:mrow> <mml:mrow><mml:mi>k</mml:mi> <mml:mi>g</mml:mi> <mml:mspace></mml:mspace> <mml:mi>g</mml:mi> <mml:mi>l</mml:mi> <mml:mi>a</mml:mi> <mml:mi>s</mml:mi> <mml:mi>s</mml:mi></mml:mrow> </mml:mfrac> </mml:mrow> </mml:math> , respectively. The difference (before and after data reconciliation) between the raw and reconciled values of energy efficiency, regenerator efficiency, and specific energy consumption were around 0.09 %, 1.58 %, and 0.86 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mfrac><mml:mrow><mml:mi>k</mml:mi> <mml:mi>J</mml:mi></mml:mrow> <mml:mrow><mml:mi>k</mml:mi> <mml:mi>g</mml:mi> <mml:mspace></mml:mspace> <mml:mi>g</mml:mi> <mml:mi>l</mml:mi> <mml:mi>a</mml:mi> <mml:mi>s</mml:mi> <mml:mi>s</mml:mi></mml:mrow> </mml:mfrac> </mml:mrow> </mml:math> , respectively. These findings underscore the importance of accurate data and the implementation of data reconciliation methods in the glass industry, providing valuable insights for improving furnace performance and energy efficiency.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2025-02-01
DOI
https://doi.org/10.1016/j.heliyon.2025.e42624
Citations
2
Primary Topic
Radiative Heat Transfer Studies
Type
article
Field-Weighted Citation Impact
2.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of electrically boosted natural gas fired glass furnace performance by using data reconciliation method

Alp Er Ş. Konukman, Neşet Arzan, Onur Kodak, Farshid Sadeghi-Khaneghah et al.
2 citations
Heliyon
Radiative Heat Transfer Studies
2.67
article

Evaluation of electrically boosted natural gas fired glass furnace performance by using data reconciliation method

Alp Er Ş. Konukman, Neşet Arzan, Onur Kodak, Farshid Sadeghi-Khaneghah, Levent Kılıç, Miraç Burak Kaya, Emre Dumankaya, Gizem Yumru Alanat
article en
2 citations

Abstract

The purpose of this study is to address the challenges posed by errors in sensor measurements and unmeasured variables in glass-melting furnaces, which can lead to misleading information regarding furnace performance. We implemented the Data Reconciliation Methodology to filter errors and estimate unmeasured variables, aiming to achieve accurate and reliable furnace characteristics. This task involved generating a dataset from measured furnace variables, and conducting observability and redundancy checks. By applying the data reconciliation method, gross errors were detected and removed, and the database was filtered for noise. Additionally, we estimated the necessary unmeasured variables. The results demonstrated the effectiveness of our approach. With accurate data, the energy efficiency, regenerator efficiency, and specific energy consumption of the furnace were found to be 38.63 %, 62.72 %, and 4159.84 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mfrac><mml:mrow><mml:mi>k</mml:mi> <mml:mi>J</mml:mi></mml:mrow> <mml:mrow><mml:mi>k</mml:mi> <mml:mi>g</mml:mi> <mml:mspace></mml:mspace> <mml:mi>g</mml:mi> <mml:mi>l</mml:mi> <mml:mi>a</mml:mi> <mml:mi>s</mml:mi> <mml:mi>s</mml:mi></mml:mrow> </mml:mfrac> </mml:mrow> </mml:math> , respectively. The difference (before and after data reconciliation) between the raw and reconciled values of energy efficiency, regenerator efficiency, and specific energy consumption were around 0.09 %, 1.58 %, and 0.86 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mfrac><mml:mrow><mml:mi>k</mml:mi> <mml:mi>J</mml:mi></mml:mrow> <mml:mrow><mml:mi>k</mml:mi> <mml:mi>g</mml:mi> <mml:mspace></mml:mspace> <mml:mi>g</mml:mi> <mml:mi>l</mml:mi> <mml:mi>a</mml:mi> <mml:mi>s</mml:mi> <mml:mi>s</mml:mi></mml:mrow> </mml:mfrac> </mml:mrow> </mml:math> , respectively. These findings underscore the importance of accurate data and the implementation of data reconciliation methods in the glass industry, providing valuable insights for improving furnace performance and energy efficiency.

HeliyonVol. 11(4)
Gebze Technical University (TR), Fatih Sultan Mehmet Waqf University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 14%
Radiative Heat Transfer Studies
2.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.