The aim of this study was to optimize a method for qualitative and quantitative determination of gaseous degradation products formed in the process of thermal decomposition in the sample. The toxicometric index was determined with the use of the coupled TG-FTIR technique (gas analyzer). The polyurethane (PUR) and polyvinyl chloride (PVC) were used for analytical studies. Based on the obtained results, it was concluded that the sample mass used for analysis, as well as the spectral range of the IR spectrum, has a crucial role in the qualitative and quantitative assessment of gaseous toxic degradation products generated during the thermal decomposition of polymeric materials. Using a gas analyzer, proprietary toxicity indices were developed, i.e., the partial toxicity index (IT<sub>PC</sub>) and total toxicity index (IT<sub>GC</sub>). It should be noted that the determined toxicity indices refer to a test sample not exceeding 10 mg. The small mass of the sample subjected to analysis allows for high resolution and repeatability of the results reading. The results of this study provide a significant methodological contribution to both the identification of gaseous degradation products formed during the thermal decomposition of materials and their quantitative detection.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2025-02-11
DOI
https://doi.org/10.3390/polym17040467
Primary Topic
Polymer Science and PVC
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative Method for Determining the Toxicometric Index of Polymer Materials with the Example of Polyurethane and Polyvinyl Chloride

A. Glowacki, Przemysław Rybiński
Polymers
Polymer Science and PVC
article

Innovative Method for Determining the Toxicometric Index of Polymer Materials with the Example of Polyurethane and Polyvinyl Chloride

A. Glowacki, Przemysław Rybiński
article en

Abstract

The aim of this study was to optimize a method for qualitative and quantitative determination of gaseous degradation products formed in the process of thermal decomposition in the sample. The toxicometric index was determined with the use of the coupled TG-FTIR technique (gas analyzer). The polyurethane (PUR) and polyvinyl chloride (PVC) were used for analytical studies. Based on the obtained results, it was concluded that the sample mass used for analysis, as well as the spectral range of the IR spectrum, has a crucial role in the qualitative and quantitative assessment of gaseous toxic degradation products generated during the thermal decomposition of polymeric materials. Using a gas analyzer, proprietary toxicity indices were developed, i.e., the partial toxicity index (IT<sub>PC</sub>) and total toxicity index (IT<sub>GC</sub>). It should be noted that the determined toxicity indices refer to a test sample not exceeding 10 mg. The small mass of the sample subjected to analysis allows for high resolution and repeatability of the results reading. The results of this study provide a significant methodological contribution to both the identification of gaseous degradation products formed during the thermal decomposition of materials and their quantitative detection.

PolymersVol. 17(4)
Jan Kochanowski University (PL)
Clean water and sanitation
Openalex Percentile: Top 98%
Polymer Science and PVC
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.