Invasive Arterial Pressure Monitoring: Are We Confident Making Decisions Based on Reliable Values?

A prerequisite for accurate invasive arterial pressure measurement is familiarity with measurement principles and pitfalls. Using an electronic survey, we assessed knowledge about invasive arterial pressure monitoring and current invasive arterial pressure monitoring practices in the ICU. The questionnaire was sent to nurses and physicians who are members of the French Intensive Care Society and the Réseau Européen de Recherche en Ventilation Artificielle network. Three hundred nine nurses and 76 physicians responded. We identified considerable gaps in knowledge and differences in practices that can significantly impact the reliability of invasive arterial pressure measurement, mainly the confusion between zeroing and leveling the transducer and the heterogeneity in external landmarks choice for the phlebostatic axis. In modern critical care, where mean arterial pressure targets are recommended and where patients are awake and/or frequently mobilized, standardized invasive arterial pressure monitoring is required.

Authors

Institutions

Publication Details

Journal
Critical Care Explorations
Published
2025-02-01
DOI
https://doi.org/10.1097/cce.0000000000001216
Citations
2
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
4.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Invasive Arterial Pressure Monitoring: Are We Confident Making Decisions Based on Reliable Values?

Frédérique Schortgen, Caroline Le Bec
2 citations
Critical Care Explorations
Hemodynamic Monitoring and Therapy
4.01
article

Invasive Arterial Pressure Monitoring: Are We Confident Making Decisions Based on Reliable Values?

Frédérique Schortgen, Caroline Le Bec
article en
2 citations

Abstract

A prerequisite for accurate invasive arterial pressure measurement is familiarity with measurement principles and pitfalls. Using an electronic survey, we assessed knowledge about invasive arterial pressure monitoring and current invasive arterial pressure monitoring practices in the ICU. The questionnaire was sent to nurses and physicians who are members of the French Intensive Care Society and the Réseau Européen de Recherche en Ventilation Artificielle network. Three hundred nine nurses and 76 physicians responded. We identified considerable gaps in knowledge and differences in practices that can significantly impact the reliability of invasive arterial pressure measurement, mainly the confusion between zeroing and leveling the transducer and the heterogeneity in external landmarks choice for the phlebostatic axis. In modern critical care, where mean arterial pressure targets are recommended and where patients are awake and/or frequently mobilized, standardized invasive arterial pressure monitoring is required.

Critical Care ExplorationsVol. 7(2)
Apple (Israel) (IL), Hôpital Intercommunal de Créteil (FR)
Intensive Care Society, Société de Réanimation de Langue Française
Good health and well-being
Openalex Percentile: Top 9%
Hemodynamic Monitoring and Therapy
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Invasive Arterial Pressure Monitoring: Are We Confident Making Decisions Based on Reliable Values? — Frédérique Schortgen, Caroline Le Bec · Critical Care Explorations (2025) | TGRS Research Map | TGRS