Reliability and Validity Examination of a New Gait Motion Analysis System

Recent advancements have made two-dimensional (2D) clinical gait analysis systems more accessible and portable than traditional three-dimensional (3D) clinical systems. This study evaluates the reliability and validity of gait measurements using monocular and composite camera setups with VisionPose, comparing them to the Vicon 3D motion capture system as a reference. Key gait parameters-including hip and knee joint angles, and time and distance factors-were assessed under normal, maximum speed, and tandem gait conditions during level walking. The results show that the intraclass correlation coefficient (ICC(1,k)) for the 2D model exceeded 0.969 for the monocular camera and 0.963 for the composite camera for gait parameters. Time-distance gait parameters demonstrated excellent relative agreement across walking styles, while joint range of motion showed overall strong agreement. However, accuracy was lower for measurements during tandem walking. The Cronbach's alpha coefficient for time-distance parameters ranged from 0.932 to 0.999 (monocular) and from 0.823 to 0.998 (composite). In contrast, for joint range of motion, the coefficient varied more widely, ranging from 0.826 to 0.985 (monocular) and from 0.314 to 0.974 (composite). The correlation coefficients for spatiotemporal gait parameters were greater than 0.933 (monocular) and 0.837 (composite). However, for joint angle parameters, the coefficients were lower during tandem walking. This study underscores the potential of 2D models in clinical applications and highlights areas for improvement to enhance their reliability and application scope.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-11
DOI
https://doi.org/10.3390/s25041076
Citations
2
Primary Topic
Gait Recognition and Analysis
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability and Validity Examination of a New Gait Motion Analysis System

Makoto Higuchi, Toshiyuki Fujiwara, Tadamitsu Matsuda, Tetsuya Takahashi et al.
2 citations
Sensors
Gait Recognition and Analysis
1.35
article

Reliability and Validity Examination of a New Gait Motion Analysis System

Makoto Higuchi, Toshiyuki Fujiwara, Tadamitsu Matsuda, Tetsuya Takahashi, Hiroshi Fukushima, Hiroyuki Daida, Tomoyuki Morisawa, Yasuo Torimoto, Takanari Matsumoto, Takehiko Kiyohara, Yuji Fujino, Kei Kakegawa, Masaki Miwa
article en
2 citations

Abstract

Recent advancements have made two-dimensional (2D) clinical gait analysis systems more accessible and portable than traditional three-dimensional (3D) clinical systems. This study evaluates the reliability and validity of gait measurements using monocular and composite camera setups with VisionPose, comparing them to the Vicon 3D motion capture system as a reference. Key gait parameters-including hip and knee joint angles, and time and distance factors-were assessed under normal, maximum speed, and tandem gait conditions during level walking. The results show that the intraclass correlation coefficient (ICC(1,k)) for the 2D model exceeded 0.969 for the monocular camera and 0.963 for the composite camera for gait parameters. Time-distance gait parameters demonstrated excellent relative agreement across walking styles, while joint range of motion showed overall strong agreement. However, accuracy was lower for measurements during tandem walking. The Cronbach's alpha coefficient for time-distance parameters ranged from 0.932 to 0.999 (monocular) and from 0.823 to 0.998 (composite). In contrast, for joint range of motion, the coefficient varied more widely, ranging from 0.826 to 0.985 (monocular) and from 0.314 to 0.974 (composite). The correlation coefficients for spatiotemporal gait parameters were greater than 0.933 (monocular) and 0.837 (composite). However, for joint angle parameters, the coefficients were lower during tandem walking. This study underscores the potential of 2D models in clinical applications and highlights areas for improvement to enhance their reliability and application scope.

SensorsVol. 25(4)
J-Power (Japan) (JP), Juntendo University (JP)
Openalex Percentile: Top 22%
Gait Recognition and Analysis
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.